Data sheet
BMA220
Page 46
BST-BMA220-DS003-08 | Revision 1.15 | August 2011 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Start R/W ACK ACK ACK
Stop
0001011 0 0011100X 11010101
S000
Slave Adress Register address (1Ch) Register data (D5h)
P
I²C write command
I²C write command only supports one byte writing. The protocol begins with start condition
generated by master, followed by 7bits slave address and a write bit (R/W = 0). The slave sends
an acknowledge bit (ACK = 0) and releases the bus. Then master sends the one byte register
address (only the first 7bits are the valid address bits, the LSB shall be ignored). The slave shall
again acknowledge the transmission and wait for the 8bits data which shall be written to the
specified register address. After slave acknowledges the data byte, master generates a stop
signal and terminates the writing protocol.
Data transferred by Master
Data transferred by Slave
Figure 22: I²C one byte write protocol