Data sheet
BMA220
Page 44
BST-BMA220-DS003-08 | Revision 1.15 | August 2011 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are subject to change without notice.
Table 21: I²C start/stop timing
Parameter Symbol Condition Min Units
START hold time T
HDSTA
0.6
START setup time T
SUSTA
0.6
STOP setup time T
SUSTO
0.6
Internal hold time T
HOLD_INT
t
f_SDA
= 100 ns
t
f_SCL
= 100 ns
0.3 (MAX)
Clock to Data Out T
VD_ACK
t
f_SDA
= 100 ns
t
f_SCL
= 100 ns
0.08
μs
Acknowledge
:
Each byte of data transferred must be acknowledged. It is indicated by an acknowledge bit sent
by the receiver. The transmitter must release the SDA line (no pull down) during the
acknowledge pulse while the receiver must then pull the SDA line low so that it remains stable
low during the high period of the acknowledge clock cycle.
SDA
By transmitter
SCK
Start condition
S
SDA
By receiver
9 8 2 1
Acknowledge
Not Acknowledge
Clock pulse for
acknowledgement
Figure 20: Waveform diagram for I²C acknowledgement on SDA
Data Transfer:
Each data bit transferred via SDA line must remain stable during high period of SCK pulse.