ICP-CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 19
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
2.13.3 Polarity (Modes)
Option Description
0 Output not used
1 Normally open, going low
2 Normally open, pulsing low
3 Normally open, one shot low
4 Normally open, one shot low (reactivate)
5 Normally open, one shot low (can reset)
6 Normally open, one shot low (alarm)
7 Normally open, latching low
8 Normally low, going open
9 Normally low, pulsing open
10 Normally low, one shot open
11 Normally low, one shot open (reactivate)
12 Normally low, one shot open (can reset)
13 Normally low, one-shot open (alarm)
14 Normally low, latching open
2.13.4 Time Base
Option Description
1 200 ms
2 1 sec
3 1 min
4 1 hr
2.13.5 Time Base Multiplier
Enter a value between 01 and 99.
2.13.6 One Shot Mode
When you program the output polarity as one shot,
the time base is multiplied by the time base
multiplier. (For example, if the time base – 2 and the
multiplier – 05, the output operates for 10 sec)
2.13.7 Pulsing Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base x the multiplier. (For example, if you
want the output to pulse 1 sec ON and 5 sec OFF,
you would program time base as one and the
multiplier as five.)
2.14 Time Programming
2.14.1 Entry Time 1
Location
466 to 467
Location Default
Increments of 1 sec (0 to 15 sec) 466 4
Increments of 16 sec (0 to 240 sec) 467 1
2.14.2 Entry Time 2
Location
468 to 469
Location Default
Increments of 1 sec (0 to 15 sec) 468 8
Increments of 16 sec (0 to 240 sec) 469 2
2.14.3 Exit Time (AWAY/STAY Modes)
Location
470 to 471
Location Default
Increments of 1 sec (0 to 15 sec) 470 12
Increments of 16 sec (0 to 240
sec)
471 3
2.14.4 Entry Guard Time For STAY Mode
Location
472 to 473
Location Default
Increments of 1 sec (0 to 15 sec) 472 0
Increments of 16 sec (0 to 240
sec)
473 0
2.14.5 Delay Alarm Report Time
Location
474 to 475
Location Default
Increments of 1 sec (0 to 15 sec) 474 0
Increments of 16 sec (0 to 240
sec)
475 0
2.14.6 Sensor Watch Time
Location
476 to 477
Location Default
Increments of days (tens digit) 476 0
Increments of days (units digit) 477 0
2.14.7 Codepad Lockout Time
Location
478
Default
0
Increments of 10 sec (0 sec to 150 sec)
2.14.8 Siren Run Time
Location
479
Default
5
Increments of 1 min (0 min to 15 min)
2.14.9 Siren Sound Rate
Location
480
Default
7
0 – Slowest frequency
15 – Fastest frequency
2.14.10 Auto Arming Pre-Alert Time
Location
481
Default
1
Increments of 5 min (0 min to 75 min)
2.14.11 Auto Arming Time
Location
482 to 485
Location Default
Hour of the day (tens digit) 482 0
Hour of the day (units digit) 483 0
Minute of the day (tens digit) 484 0
Minute of the day (units digit) 485 0
Comentarios a estos manuales