2.6.4 Zone Pulse Count Time
Option 20 ms Loop
Response Time
Option 150 ms Loop
Response Time
0 0.5 sec 8 20 sec
1 1 sec 9 30 sec
2 2 sec 10 40 sec
3 3 sec 11 50 sec
4 4 sec 12 60 sec
5 5 sec 13 90 sec
6 10 sec 14 120 sec
7 15 sec 15 200 sec
2.6.5 Zone Options 1
Option Description
1 Lockout siren/dialer
2 Delay Alarm report
4 Silent alarm
8 Sensor watch
2.6.6 Zone Options 2
Option Group
1 Isolated in STAY Mode 1
2 Zone isolation allowed
4 Forces arming allowed
8 Zone Restore Report allowed
2.6.7 Zone Dialer Options
Option Description
0 No zone reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.6.8 Keyswitch Zone Options
The keyswitch zone options replace Zone Options 1
only for the zones that were programmed to operate
as a keyswitch zone.
Option Description
0 Latching arm and disarm in AWAY Mode
1 Latching arm in AWAY Mode
2 Latching disarm from AWAY Mode or STAY
Mode
4 Latching arm and disarm in STAY Mode
5 Latching arm in STAY Mode
6 Latching disarm from STAY Mode
8 Momentary arm and disarm in AWAY Mode
9 Momentary arm in AWAY Mode
10 Momentary disarm from AWAY Mode or STAY
mode
12 Momentary arm and disarm in STAY Mode
13 Momentary arm in STAY Mode
14 Momentary disarm from STAY Mode
2.7 Swinger Programming
2.7.1 Swinger Shutdown Count For Siren
Location
379
Default
3
1 to 15 Number of times siren operates until lockout
2.7.2 Swinger Shutdown Count For Dialer
Location
380
Default
6
1 to 15 Number of times dialer operates until lockout
2.8 Zone Status Programming
2.8.1 Zone Status – Zone Tamper Report
Location
381 to 382
Location Default
Zone Tamper Report 381 0
Zone Tamper Restore Report 382 0
2.8.2 Zone Status – Walk Test Report
Location
383 to 384
Location Default
Walk Test Start Report 383 0
Walk Test End Report 384 0
2.8.3 Zone Status – Bypass Report
Location
385 to 386
Location Default
Zone Bypass Report 385 9
Zone Bypass Restore Report 386 8
2.8.4 Zone Status – Trouble Report
Location
387 to 388
Location Default
Zone Trouble Report 387 2
Zone Trouble Restore Report 388 3
2.8.5 Zone Status – Sensor Watch Report
Location
389 to 390
Location Default
Sensor Watch Report 389 4
Sensor Watch Restore Report 390 5
2.8.6 Zone Status – Alarm Restore Code
Location
391
Default
14
2.8.7 Zone Status Reporting Options
Location
392
0 No zone status reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
2.9 RF Programming
2.9.1 RF Supervision Time
Location
393
Default
0
Increments of 6 hrs. (0 to 90 hrs.)
2.9.2 RF Low Battery Report
Location
394 to 395
Location Default
RF Low Battery Report 395 6
RF Low Battery Restore Report 395 8
Comentarios a estos manuales