ICP-CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 21
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
2.16 Zone Allocations Programming
2.16.1 Zone Allocations Enabled for Area 1
and Area 2
Location
502 to 517
Default
0 0 0 0 0 0 0 0
Location 502 Area 1 – Zone 1 indicator
Location 503 Area 1 – Zone 2 indicator
Location 504 Area 1 – Zone 3 indicator
Location 505 Area 1 – Zone 4 indicator
Location 506 Area 1 – Zone 5 indicator
Location 507 Area 1 – Zone 6 indicator
Location 508 Area 1 – Zone 7 indicator
Location 509 Area 1 – Zone 8 indicator
Location 510 Area 2 – Zone 1 indicator
Location 511 Area 2 – Zone 2 indicator
Location 512 Area 2 – Zone 3 indicator
Location 513 Area 2 – Zone 4 indicator
Location 514 Area 2 – Zone 5 indicator
Location 515 Area 2 – Zone 6 indicator
Location 516 Area 2 – Zone 7 indicator
Location 517 Area 2 – Zone 8 indicator
0
1
Not mapped for this LED
This LED used, a zone is mapped to it
2.16.2 Zone Allocations for Area 1 and Area 2
Location
518 to 533 Refer to page 13
Default
0 0 0 0 0 0 0 0
Location 518 Area 1 – Zone 1 indicator
Location 519 Area 1 – Zone 2 indicator
Location 520 Area 1 – Zone 3 indicator
Location 521 Area 1 – Zone 4 indicator
Location 522 Area 1 – Zone 5 indicator
Location 523 Area 1 – Zone 6 indicator
Location 524 Area 1 – Zone 7 indicator
Location 525 Area 1 – Zone 8 indicator
Location 526 Area 2 – Zone 1 indicator
Location 527 Area 2 – Zone 2 indicator
Location 528 Area 2 – Zone 3 indicator
Location 529 Area 2 – Zone 4 indicator
Location 530 Area 2 – Zone 5 indicator
Location 531 Area 2 – Zone 6 indicator
Location 532 Area 2 – Zone 7 indicator
Location 533 Area 2 – Zone 8 indicator
0-15 Mapping zone 1-16 to this LED
2.17 User Code Area Assignment
Location
534 to 549
Location Default
User Code 1 534 0
User Code 2 535 0
User Code 3 536 0
User Code 4 537 0
User Code 5 538 0
User Code 6 539 0
User Code 7 540 0
User Code 8 541 0
User Code 9 542 0
User Code 10 543 0
User Code 11 544 0
User Code 12 545 0
User Code 13 546 0
User Code 14 547 0
User Code 15 548 0
User Code 16 549 0
0 User code not assigned
1 User code assigned to Area 1
2 User code assigned to Area 2
3 User code assigned to both Area 1 and Area 2
2.18 Domestic Telephone Numbers
Location
550 to 597
2.19 Reserved
Location
598
Default
0
2.20 RF Programming
2.20.1 RF Options
Location
599
Default
0
1 Sound siren on RF Receiver fail
2 Sound siren on RF Receiver tamper/jamming
4 Unseal zone that fails supervision (if supervision
enabled)
8 RF jamming monitoring allowed
Comentarios a estos manuales