D7212GV2 | Operation and Installation Guide | 4.0 Installation
.
Bosch Security Systems, Inc. | 2/07 | F01U003805-02 19
4.10 Service Walk Test
The Service Walk Test differs from the standard Walk
Test. In the standard Walk Test, POPITs whose
switches are set for a point number not programmed in
the control panel do not appear in the test. In the
Service Walk Test, POPITs whose switches are set for a
point number that is not programmed in the control
panel do appear in the test.
The Service Walk Test allows the installer to walk test
all points from a control-panel-wide keypad, regardless
of the point index type.
A Service Walk Test can also be initiated by account-
wide or area-wide keypads but test only those points
that are within the scope of the keypad that initiated
the function. The Service Walk Test does not test
points in armed areas.
Only Walk Test Start and Walk Test End
are reported to the central station.
The D9131A can be configured for local
printing. Refer to the D7212GV2 Program
Entry Guide (P/N: F01U003804).
During a Service Walk Test, the summary
alarm and summary fire remain off, because
there are no Fire or Burg alarm conditions
to summarize. The P# Relay Response
Type feature operates as programmed.
Service Walk Test Procedure
Refer to Figure 7 on page 20 for Service Walk Test
options. Refer to the Walk Test procedures in the GV2
Series Owner’s Manual Supplement (P/N: F01U063791)
when using a D1260 or D1260B Keypad.
1. Choose a keypad to conduct the test. Ensure that
the display shows the idle disarmed text.
2. Press the [MENU] key to enter the Function List.
Press [NEXT] repeatedly until the SERVICE
WALK ? prompt appears.
3. Press [ENT].
The D7212GV2 does not include the
Service Walk Test in the Service Menu.
Enabling the Service Walk Test function
Function List provides access to the
Service Walk Test.
4. The display shows ### PTS TO TEST .Test the
first detection device.
5. When a detection device is faulted, the keypad
emits a brief tone and displays the point text of the
point tested for 60 seconds. After 60 seconds, the
display returns to the ### PTS TO TEST
message.
Extra Points display default text: If the switches on
a POPIT are set incorrectly to a point number that is
not in the program for the control panel, the default
text for that point number (PT ###) appears when the
point is faulted. Refer to the control panel’s program
record sheet for the default text for all points.
Faulting the point a second time produces the tone and
shows the point text, but does not decrease the count in
the ## PTS TO TEST message.
5. To see the points that remain untested during the
Service Walk Test:
a. Press [ESC] when point text appears. The
display shows ## PTS TO TEST.
b. Press the [ESC] key. VIEW UNTESTED ?
appears.
c. Press [ENT]. ## PTS UNTESTED appears.
d. Press [NEXT] to see a list of the points that
have not yet been tested. Move through this
list by pressing the [NEXT] key.
e. To resume the Service Walk Test, press [ESC].
## PTS UNTESTED appears.
f. Press [ESC]. ## PTS TO TEST appears.
g. Resume testing points. To end the Service
Walk Test, press [ESC] twice.
6. After the last point is tested, 0 PTS TO TEST
appears. Press [ESC]. The display shows ALL PTS
TESTED briefly before returning to idle text.
Automatic time-out returns the system to
idle text. If there is no point or keypad
activity for 20 min, the Service Walk Test
ends automatically. The keypad returns to
idle text.