D7212GV2 | Operation and Installation Guide | 13.0 Programmer Connections
.
Bosch Security Systems, Inc. | 2/07 | F01U003805-02 51
12.5.2 Network Interface Modules
The Bosch Security Systems, Inc. DX4020 Network
Interface Module is a four-wire powered SDI device
that provides connection for two-way communication
over Ethernet networks to the D7212GV2.
For programming information on enhanced
communications, refer to the D7212GV2 Program Entry
Guide (P/N: F01U003804).
The DX4020 can be installed up to 305 m (1000 ft)
from the control panel using 0.8 mm (22 AWG) wire.
The D9133TTL-E can be installed up to 305 m (1000
ft) from the control panel using 1.2 mm (18 AWG)
wire.
12.5.3 Address Settings
The DX4020 has specific DIP switch settings for SDI
Address 88 when using the DX4020 for Remote
Programming Software (RPS) or enhanced
communications in a local area network (LAN) or
wide-area network (WAN) environment. Refer to
Figure 26 for the correct switch settings.
Figure 26: DX4020 DIP Switch Settings
2
=
3
=
4
R
Y
G
B
1
OPEN
123456
78
1 - DIP Switches
2 - ON position
3 - OFF position
4 - SDE Address 88 switch settings
12.5.4 Supervision
Supervision of the DX4020, D9133DC, and
D9133TTL-E at SDI Address 88 is available through
programming that ensures operation between the
module and the control panel.
If supervised and the module does not respond to
control panel supervision polls,
SERVC SDI 88
appears at the keypad. The report to the receiver
includes the address of the troubled module indicating
which module needs service.
13.0 Programmer Connections
13.1 Programmer Connector
Refer to the D5200 Operation Manual
(P/N: 74-06176-000) for complete information on using
the D5200 programmer.
To connect and disconnect the programmer:
1.
Lock the Reset Pin (Figure 27).
2.
Connect the D5200 Data/Power cord to the
programming connector on the control panel.
3.
Perform the desired programming function (send
or receive program).
4.
Disconnect the programmer.
Figure 27: Reset Pin
Reset Pin
Disable All Except Battery
Charging And Programming
PERIPHERAL DEVICE CONNECTIONS
RED POWER +
YELLOW DATA BUS A
GREEN DATA BUS B
BLACK COMMON
32
31
30
29
1
2
1 - Reset Pin locked (closed)
2 - Reset Pin normal (open) for normal control
panel operation
13.2 Programmer Access Reports
When a program is sent to the control panel, the
control panel sends a
Prog Access OK report ten
seconds after the handler exits or when the
programmer disconnects. The prompt in routing must
be programmed Yes to send this report.