Table 25: Output Function Types (continued)
Digit 1 Digit 2 Function Type Description
5 1 Trouble Zone Function 1
to
5 15 Trouble Zone Function 15
These 15 output functions activate for troubles on any zone assigned to
the specified Zone Function. They reset when none of the zones assigned
to the specified Zone Function are in trouble.
6 0 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).
6 1 Follow PIN 1
to
6 15 Follow PIN 15
7 0 Follow PIN 16
to
7 15 Follow PIN 31
8 0 Follow PIN 32
These output functions activate when the specified PIN is entered.
Output Function Type 7, 12 follows User 28, which can be programmed
as the Guard Code User (see page 74).
These output types are event-driven. See Mode (Steady, Pulse, One
Shot), Output ## on page 117 for more information.
PIN area assignments are ignored when these output functions are
selected.
8 1 Sked Only This output type is only available for Outputs 1 to 15. Activated by Skeds.
See Assign (Area or Output), Sked # on page 121 for more information.
8 2 Change Outputs Activated/deactivated by Change Outputs function ([#][5][4]).
8 3 Always On Output is always activated.
8 4 Verified Alarm Activates when the requirements for a verified alarm are met. Resets
when a PIN is entered.
8 5 Unverified Alarm Activates on any non-24-hr alarm, 24-hr tamper or 24-hr burglary alarm.
Resets when the verified alarm timer resets or when a PIN is entered.
8 6 Tamper Activates on any tamper condition. Resets when the tamper condition
restores.
8 7 Bypass Activates when any input is bypassed. Resets when all input bypasses
are cleared.
8 8 Enhanced Siren Activates on Exit Delay, Entry Delay, Chime, Alarm, Tamper, Trouble, or
Bad Set. Resets at the end of bell time or when a PIN is entered.
8 9 Alarm Cancel Activates on a cancelled alarm. Resets when alarm is cleared.
8 10 RF Transmitter Missing Activates when any RF transmitter is missing. Restores by pressing the
[System Reset] key.
8 11 RF Transmitter Low Battery Activates when any RF transmitter is reporting a low battery. Resets by
pressing the [System Reset] key.
8 12 RF Receiver Jamming Activates when RF Jamming is present. Resets by pressing the [System
Reset] key.
8 13 Fire Alarm Only Activates on Fire Alarm only. PIN resets. Does not pulse in Temporal
Code 3 format.
8 14 Personal Alarm Activates when one of its assigned areas is set to Personal Alarm. Resets
by entering a valid user PIN, pressing [System Reset], or by RPS (System
Reset command). Activates on any of the following conditions: (1) If a
Duress User PIN is entered (2) If an Emergency key is active in an area
and “Activate Panic Alarm Response” and “Alarm Output” are enabled for
the key (3) If a RF keyfob reports a Panic alarm (4) If a zone configured
for 24-hr Visible Panic (Zone Function Type 6) goes into alarm, or (5)
Certain [Q] button configurations. See Q Button Configuration on page
76.
8 15 [Q] Button Output activates when [Q] is pressed on a RF keyfob. For Steady or
Pulse modes, [System Reset] resets. This output function type is event-
driven. See Mode (Steady, Pulse, One Shot), Output ## on page 117
for more information.