DS7200V2-EXP | Expert Programming Guide | 4. Control Panel Programming EN | 136
Bosch Security Systems | 8/04 | 4998153891C
Keypad/Door Access Control Module (DACM) Area Options
• Address:
Keypad/DACM 1: 0679
Keypad/DACM 2: 0681
Keypad/DACM 3: 0683
Keypad/DACM 4: 0685
Keypad/DACM 5: 0687
Keypad/DACM 6: 0689
Keypad/DACM 7: 0691
Keypad/DACM 8: 0693
• Default:
Keypad/DACM 1: 1 (Device is a keypad/DACM assigned to Area 1)
Keypads/DACMs 2 to 8: 0 (No keypad/DACM assigned)
• Selections: 0 to 4, 9 to 12
Enter This Data Digit to Select Options
Keypad/DACM Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Keypad/DACM not assigned (disabled)
•
Assign Keypad/DACM to Area 1
•
•
Assign Keypad/DACM to Area 2
•
•
Assign Keypad/DACM to Area 3 (DS7240V2 only)
•
•
Assign Keypad/DACM to Area 4 (DS7240V2 only)
•
•
Device is a Keypad
• • • •
Device is a DACM
• • • •
This parameter identifies the device connected to the control panel’s Data Bus (Addresses 1 to 8) as a DACM, and
assigns the DACM to an area.
The control panel supervises the connection to the DACM. If it fails to communicate with the control panel, the
control panel sends a “DBus Missing” {125} report.
DACM Location Assignment
• Address:
− DACM 1: 3546 to 3547
− DACM 2: 3548 to 3549
− DACM 3: 3550 to 3551
− DACM 4: 3552 to 3553
− DACM 5: 3554 to 3555
− DACM 6: 3556 to 3557
− DACM 7: 3558 to 3559
− DACM 8: 3560 to 3561
• Default: 0,0
• Selections:
− DS7240V2: 0,0 to 4,0
− DS7220V2: 0,0 to 2,4
A DACM door contact can occupy any location in the control panel. Use this parameter to assign a control panel
location to a DACM door contact.