Bosch DS7200V2-EXP Guía de usuario Pagina 143

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 142
DS7200V2-EXP | Expert Programming Guide | 5. Reference Materials EN | 143
Bosch Security Systems | 8/04 | 4998153891C
Table 31: Control Panel Events and Reporting Formats (continued)
Event Event as shown in
Control Panel Log
SIA Report Contact ID
Report
Event Description Zone Types
Linked to Event
RPS
Event
Group
Status
Report
91 Open,Usr
OP Opening
Report
401 O/C by
User
Opening by user, by ID reported. 10
92 Open,KS
OS Opening
Keyswitch
409 Keyswitch
O/C
Opening by Keyswitch. 10
93 Open,Skd,Alarm
OR Disarm from
Alarm
403 Automatic
O/C
Opening after Alarm event by Sked. 10
94 Open,RPS,Alarm
OR Disarm from
Alarm
400
Open/Close
Opening after Alarm event by RPS.
95 Open,Usr,Alarm
OR Disarm from
Alarm
401 O/C by
User
Opening after Alarm event, ID
reported.
10
96 Open,KS,Alarm
OR Disarm from
Alarm
409 Keyswitch
O/C
Opening after Alarm event by
Keyswitch.
10
97 Reserved
98 Params Changed
YG Parameter
Changed
306 Panel
Programming
Changed
Panel parameters changed. 12 R
99 Phone Line Fail
LT Phone Line
Trouble
351 Telco 1
fault
Phone line voltage less than 3 V for
40 sec.
12 R S
100 Phone Line Rstl
LR Phone Line
Restoral
351 Telco 1
fault
After Phone Line Fail event, phone
line voltage detected at greater
than 3 V for 40 sec.
12 R S
101 Bad Call to RPS
RA Remote
Programmer Call
Failed
413
Unsuccessful
access
Panel attempted call to RPS, but
was unsuccessful.
12 R
102 RPS Access Fail
RU Remote
Program Fail
413
Unsuccessful
access
RPS attempted to connect to panel
but was not successful.
R
103 RPS Access OK
RS Valid Remote
Access
412
Successful
Download/
Access
RPS successfully connected to
and disconnected from panel.
R
104 Re-Boot,Panel RR Power Up
305 System
reset
Normal start up or reset after
programming.
R S
105 Re-Boot,DBus RR Power Up
339 Exp.
Module Reset
Unexpected reset (reboot) from
Data Bus device.
12 R S
106 Output Reset,Usr RO Relay Open
320
Sounder/Relay
Output Reset by User. 16 R
107 Output Reset,Skd RO Relay Open
320
Sounder/Relay
Output Reset by Sked. 16 R
108 Output Reset, RPS RO Relay Open
320
Sounder/Relay
Output Reset by RPS. R
109 Output Set,Usr RC Relay Close
320
Sounder/Relay
Output Set by User. 16 R
110 Output Set,Skd RC Relay Close
320
Sounder/Relay
Output Set by Sked. 16 R
111 Output Set,RPS RC Relay Close
320
Sounder/Relay
Output Set by RPS. R
112 Rstrl,Tamper
TR Tamper
Restoral
137 Tamper
Restoral from alarm, Tamper zone
type.
4- Tamper 8
113 Rstrl,Emergency
QR Emergency
Restoral
101 Personal
Emergency
Restoral from alarm, Emergency
zone type.
5- Emergency 8
114 Rstrl,Panic
PR Panic
Restoral
120 Panic
Restoral from alarm, Panic zone
type.
6- Visible Panic 8
Vista de pagina 142
1 2 ... 138 139 140 141 142 143 144 145 146 147 148 ... 155 156

Comentarios a estos manuales