Delay Short - Y or N: This parameter will program in a delay in the respective input that will retard the reporting of
the input when tripped.
Fault Short - Y or N: Fault Short specifies whether the status of the Input will be treated as a fault when a Short
condition is detected across the EOL resistor on the specified Input . When the input is configured for expanded, the
Primary and Expanded Loops will be individually monitored and a separate message will be reported when a Short
condition is detected. “YES” = A Priority Alert message will blink and an audible tone will sound on the SC9000
computer.
Mask Short- Y or N: Mask short allows the operator to command any or all inputs monitored by the SC2104 to only
report input trips if the phone line is cut. As long as the phone line is good, the SC2104 will ignore any trips on a
MASKED input.
Delay Open - Y or N: This parameter will program in a delay in the respective input that will retard the reporting of
the input when tripped.
Fault Open- Y or N: Fault Open specifies whether the status of the Input will be treated as a fault when an Open
condition is detected on the specified Input .When the Input is configured for expanded, the Input will be treated as a
fault if an Open is detected on either the primary or the expanded loop. “YES” = A Priority Alert message will blink
and an audible tone will sound on the SC900 computer.
Mask Open- Y or N: Mask open allows the operator to command any or all inputs monitored by the SC2104 to only
report input trips if the phone line is cut. As long as the phone line is good, the SC2104 will ignore any trips on a
masked input.
Input XLAT - 00 to 4F: The Input Translation Table (XLAT) specifies the English plain text definition that you wish to
assign to an INPUT. The text will be displayed in place of the default messages “Open, Short, or Normal”. The Input
Translation Table has 5 pages, with 16 line numbers per page, for a total of 80 line numbers. Each line provides a
maximum of 8 characters of English text translation for Normal, Open, and Short Input conditions. The corresponding
text assigned to the respective Input in the translation table is only for display at the SC9000 computer. It is not part
of the message sent to the Automation software. Input translation gives the operator the ability to allow an input on an
SC2104 to report “TEMP HI” or “TEMP LO” instead of “INPUT SHORT” or “INPUT OPEN”. This ability can be very
useful for processing alarm messages in the unlikely event of an automation system failure. Each translation table
(XLAT) line contains three available conditions that the operator must define, “SHORT, OPEN, & NORMAL”. These
are the only conditions the SC2104 can detect and report on it’s inputs.
NOTE: The SAFECOM ST150 v1.00 and higher software default values for all new Radio Communicator input
translation tables are “ 00 “ and the default values for line #00, in the Input Translation Table, are NORMAL, OPEN, and
SHORT.
4.1.3. Remote Status Display – the SC2104 Radio Communicator’s Response to a Manual “Poll” by the
Operator
If the Central Station operator performs a manual poll of a Radio Communicator, the remote status display comes up on
the screen to show the operator the exact status of the Radio Communicator in the field. The Remote Status display
allows the operator to individually control and monitor the status of an SC2104. The following is a description of those
items available for viewing and control on the Remote Status display (See the diagram below and the following
explanation):