SC9000
ST150 SAFECOM Central Station Operation Manual
4998122249B Page 24 © 2002 Radionics
Bypassing SC2104 Inputs from the SC9000
The SC9000 provides the operator with the option of sending a command to an SC2104 instructing it to BYPASS
reporting any changes to a specific input. This function may be necessary when a faulty detector has been identified, or if
the SC2104 is currently being serviced and the signals that would normally be sent are not desired. Some Central Station
operators refer to this mode as “TEST MODE” indicating that the SC2104 will not send any input messages to the
SC9000 when tripped.
To Send a Manual Input Bypass Command
1. Press the F1=SELECT option from the System Status Menu Command Window. The Select a Remote menu will be
displayed. Enter the Radio Communicator number in the “Select a remote:” field and press ENTER.
2. The operator message “Polling remote XXX depress ALT-X to fail. . .” is displayed until an acknowledge (ACK)
message is received from the SC2104; then the Remote Status screen will be displayed allowing the operator to view
the status of the SC2104.
3. Using the “
↓↑
” keys position the cursor on the desired input to bypass field. That input to be bypassed field will be
highlighted light blue to indicate a modification may be made by the operator. Then press the SPACE bar once. The
operator prompt “Transmitting to remote XXX, depress ALT-X to fail ...” is displayed until an ACK is received from the
SC2104.
4. The SC2104 will bypass the input selected and send the “Input X BYPASSED” message to the SC9000 computer.
This input is now bypassed and will not report any input trips on this specific input.
NOTE: In the event of a SC2104 Restart (complete AC and BATTERY removal), all of the Inputs will return to normal
reporting of status changes.
To Send a Manual Input Un-Bypass Command (Reverse a Bypass Command)
1. Press the F1=SELECT option from the System Status Menu Command Window. The Select a Remote menu will be
displayed. Enter the Radio Communicator number in the “Select a remote:” field and press ENTER.
2. The operator message “Polling remote XXX depress ALT-X to fail. . .” is displayed until an acknowledge (ACK)
message is received from the SC2104; then the Remote Status screen will be displayed allowing the operator to view
the status of the SC2104.
3. Using the “
↓↑
” keys position the cursor on the desired input to unbypass. That input to be unbypassed will be
highlighted light blue to indicate a modification may be made by the operator. Then press the SPACE bar once. The
operator prompt “Transmitting to remote XXX, depress ALT-X to fail ...” is displayed until an ACK is received from the
SC2104. The SC2104 will then unbypass the input selected and send the “Input X unbypassed” message to the
SC9000 computer. The reporting of status changes to that input has now been restored to normal input reporting or
unbypassed reporting.
4.2 SC8016
4.2.1 SC8016 Full Data Transfer Communicator Overview
The SC8016 Radio Communicator is located at a customer site; commercial or residential. The SC8016 is a high security
control dialer based on the Solution-16 platform, which uses supervised bi-directional radio signaling to communicate with
the control room using Contact ID format.