SC9000
ST150 SAFECOM Central Station Operation Manual
4998122249B Page 40 © 2002 Radionics
NNN priority granted - Priority #3
- Not Sent to Automation - High Priority Polling Status has been granted by the
SC9000 to a requesting Radio Communicator. The request is sent by the Radio Communicator at the moment the
Alarm Panel Dialer starts to dial the programmed phone number after Line Seizure.
NNN priority pended - Priority #1
- Not Sent to Automation - The SC9000 has TEMPORARILY Denied a Radio
Communicators' request for High Priority Polling Status. Priority Pended is initiated if the number of Radio
Communicators requesting High Priority Polling Status has exceeded the value programmed in this field. The Radio
Communicator is placed on a sequential (FIRST IN/FIRST OUT) Priority Pended list until a High Priority Polling
Status becomes available.
NNN PRODUCT ID XXXX? - Priority #1
- Not Sent to Automation - The Radio Communicator is in the startup mode
and has reported a PID that does not match the PID on the Radio Communicator account Setup Menu #1. Since the
Product ID is incorrect, the startup programming cannot continue. Only the first 3 characters of the PID are used for
matching criteria.
NNN program complete - Priority #2
- Not Sent to Automation - The Radio Communicator has sent an ACK message
in response to download programming message(s) sent by the SC9000. The Program Complete message verifies
that the Radio Communicator CPU has accepted and is programmed with all of the new parameters or modifications
to the existing parameters contained in the Radio Communicator account Setup Menu(s) assigned to the Radio
Communicator.
NNN REMOTE COM ERRORS - Priority #1
- Not Sent to Automation - The Radio Communicator is currently having
difficulty in establishing radio communications with the SC9000. The problem is an indication that the voluntary
message from the Radio Communicator is received by the SC9000, but the Radio Communicator has not received
the ACK message sent by the SC9000. The SC9000 has received 6 to 7 duplicate messages from the Radio
Communicator.
NNN REMOTE COM TROUBLE - Priority #1
- Not Sent to Automation - The Radio Communicator has declared
radio communications failure with the SC9000 Receiver. Remote Com Trouble is initiated by the Radio
Communicator when it has not received an ACK message from the SC9000 in response to a series of Radio
Communicator initiated messages, regardless of the reason. The Remote Com Trouble message will be received
and displayed by the SC9000 when radio communications is finally restored with the SC9000.
NNN remote com restore - Priority #2
- Not Sent to Automation - Cancels a previously reported Remote Com Trouble
message from a Radio Communicator. Two-way radio communications with the SC9000 Receiver has now been
restored.
NNN restart - Priority #2
- The Radio Communicator has been restarted due to turning system power-on, recycling
the system power, or a reset of the CPU.
NNN RF restore - Priority #2
- Cancels a previously reported RF Trouble message by the SC9000. Two-way radio
communications with the Remote SC9000 has now been restored.
NNN RF trouble - Priority #1
- The SC9000 has declared radio communications failure with the Radio Communicator,
regardless of the reason. RF Trouble is initiated by the SC9000 when it has not received an ACK message from the
Radio Communicator in response to a message or supervisory poll after the number of Attempts, time for Delay, and
number of retries has expired.
**** screen dump - Priority #3
- Not Sent to Automation - A menu on the Operator Window was printed via the Print
Screen key. Used to time stamp screen dumps.
**** select User Name - Priority #3
- Not Sent to Automation - Initiated by the SC9000 when an operator, that is
logged in with Authority Levels #0 or #1 selects a Radio Communicator for Status viewing and control.
NNN SHORT: input # - Priority #2
- The Radio Communicator has detected a Short condition on Input #. The default
text SHORT may be replaced with an Input XLAT entry. This message will behave as a Priority Alert #1 if the Input
Fault Short is set to " Y " on the Remote Setup Menu. Input # is displayed for NON-Expanded Inputs and Input #X for
Expanded Inputs.
**** S H U T D O W N - Priority #2 - Not Sent to Automation - The ST150 SAFECOM software has been Shut Down
by an operator initiated command. This is not applicable when the Shut Down occurs due to turning the computer
system power Off.
**** S T A R T U P - Priority #2
- The ST150 SAFECOM software has been Started Up due to a system power-on,
recycling the system power or a reset of the CPU.
NNN startup XXXXXXXXX - Priority #2
- Not Sent to Automation - A Radio Communicator is in the startup mode and
is transmitting a startup initialize message. Startup XXXXXXXXX is initiated when the Radio Communicator is initially
powered up or when the CPU is Reset. XXXXXXXXX is the S/N of the CPU.
NNN tamper fault - Priority #1
- The Radio Communicator panel door has been Opened.