AMAX panel 2000 / AMAX panel 2000 EN System Informations 1 | en 51
Bosch Sicherheitssysteme GmbH Installation Manual F.01U.241.127 | V4 | 2011.12
EEE = Event Code
GG = Group Number (always 0)
CCC = Zone/ Contact ID, 000 is for no zone/ID message
S = Checksum digit
Note: Any 0 values must be sent as an 0x0A.
Contact ID Report Data:
7.6.3 CFSK Format
The CFSK communication format is a protocol based on the standard Bell 103 FSK (Frequency
Shift Keying) modulation, as detailed by the SIA (Security Industry Associaton) “Digit
Communications Standard” November 1991.
CFSK Message Format(6/2)
B AAAAAA TE S
B = Begin ( 1 byte, always 04 )
AAAAAA= Subscriber ID (3 bytes)
T= Type of Event Code ( 1 byte)
E= Event/User/ Zone number (1 byte)
S= Checksum digit (1 byte)
Formular S = Sum of message bytes & 0xFF
Remark:
7.7 Dialer Information
This section outlines the programming information required for the AMAX panel 200 / AMAX
panel 2000 EN when communicating with a base station receiver. These parameters specify
the telephone numbers/IP address to be called, transmission formats and internet
communication options.
The control panel can report event information from four on-board dialers. The dialers report
to Receiver 1 to Receiver 4 by programming. You can program each dialer with 4 separate
telephone numbers/IP addresses and ports, reporting format type and subscriber ID number,
and internet communication options if necessary.
Example
You can set up Dialer 1 to report to receiver 1 in CFSK Format and set up Dialer 2, Dialer 3 and
Dialer 4 to report to a base station receiver in Contact ID Format only if Dialer 1 is
unsuccessful.
To program a telephone number:
Each location in the telephone numbers stores one digit of the telephone number.
Insert a 15 at the end of a telephone number to indicate to the dialer that the end of the
telephone number is reached. The dialing sequence is terminated when a 15 appears.
Example
To program the telephone number 9672 1055 as the Telephone Number for Receiver 1,
program the following sequence into Location 000 - 016:
[9 6 7 2 1 0 5 5 15 x x x x x x x x]x stands for any digit.To enter a 4-sec pause in the
dialing sequence, program a 13. A pause might be necessary when the dialer communicates
through an old (slower) telephone exchange or when a PABX system is in place.
Example
To program the number 02 pause 9672 1055, enter:
[0 2 13 9 6 7 2 1 0 5 5 15 x x x x x].
Table 7.1 shows how to program the numbers, keys, and functions for a telephone number.