90 en | Troubleshooting AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12 Installation Manual Bosch Sicherheitssysteme GmbH
Battery fault still
indicates after replaced
with new battery.
– System test the battery each time arming or every time set
in location 191. Only after testing the battery fault can be
cleared away.
– Voltage of the new battery reaches the normal value after it
is charged for some time.
Control Panel does not
dial.
– Check if the dialing function is switched off in
communication programming (Telephone number and
transmission format need to be programmed).
No remote arming
function.
– Check if the function is switched off (Do not set Location
152 and 153 as 0).
No RPS software
function.
– Check if the function is switched off (Do not set Location
152 and 153 as 0).
Abnormal in PSTN/
Domestic dialling
communicaiton.
– When extention system is used in telephone network,
dialing delay needs to be added in programming.
– Network supports the ADSL at the same time, the control
panel needs to be connected through the ADSL filter .
Trouble Causes & Measures