82 en | Programming sheets AMAX panel 2000 / AMAX panel 2000 EN
F.01U.241.127 | V4 | 2011.12 Installation Manual Bosch Sicherheitssysteme GmbH
10.3.16 AC Fault Detect time
10.3.17 Battery Detect time
10.3.18 Event Record Count Per Set/Unset Period
10.3.19 Beep for Warning Devices
10.4 Zone Programming
Location 189-190 Location Default
0-60 Minutes 189-190 10
Location 191 Location Default
1-15 min 191
1
EN=15
Location 192 Location Default
3-10 192 3
Location 193 Location Default
0=Disable 1=Enable 193 0
Location 210-289
Zone Location Default
Zone #01
Zone Type (Refer to zone type option) 210 3
Zone Bypass (Disable=0, Enable=1) 211 1
Forced Arming (Disable=0, Enable=1) 212
1
EN=0
Silent Alarm (Enable=1, Disable=0) 213
0
EN=0
Zone alarm lock out time (Disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=4)
214 0
Support Detector Tamper (Disable=0, Enable=1) 215 1
Zone alarm report (Refer to zone report option) 216
6
EN=1/5/
6/7
Zone Chime Mode (Enable=1, Disable=0) 217 0
Reserved 218-219 0
Zone #02
Zone Type (Refer to zone type option) 220 1
Zone Bypass (Disable=0, Enable=1) 221 1
Forced Arming (Disable=0, Enable=1) 222
1
EN=0
Silent Alarm (Enable=1, Disable=0) 223
0
EN=0
Zone alarm lock out time (disable=0, 1 times=1, 3 times=2, 6
times=3, alarm duration=3)
224 0
Support Detector Tamper (Disable=0, Enable=1) 225 1
Zone alarm report (Refer to zone report option) 226
6
EN=1/5/
6/7
Zone Chime Mode (Enable=1, Disable=0) 227 0