ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters
Bosch Security Systems, Inc. | 12/08 | F01U089402-02 11
Location
Function
Options/Notes Default
346 to 347
System Status – AUX Power Supply Fail Restore
Report
Location 346: tens digit
Location 347: units digit
10
8
348 to 349
System Status – AC Fail Report
Location 348: tens digit
Location 349: units digit
10
2
350 to 351
System Status – AC Fail Restore Report
Location 350: tens digit
Location 351: units digit
10
7
352 to 353
System Status – Low Battery Report
Location 352: tens digit
Location 353: units digit
10
1
354 to 355
System Status – Low Battery Restore Report
Location 354: tens digit
Location 355: units digit
10
6
356 to 358
System Status – Access Denied (Code Retry)
Location 356: Code retry limit (0 = unlimited)
Location 357: tens digit
Location 358: units digit
6
7
12
359
System Status Reporting Options
0 No System Status Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
1
360 to 366
Test Report Time (Automatic)
Location 360: Hour of day (tens digit)
Location 361: Hour of day (units digit)
Location 362: Minute of day (tens digit)
Location 363: Minute of day (units digit)
Location 364: Test Report (tens digit)
Location 365: Test Report (units digit)
Location 366: Repeat interval in days
0
0
0
0
7
1
0
367
Test Reporting Dialer Options
0 No Test Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
1
368 to 397
Outputs
Output 1 (Default = Horn speaker) (368 to 373)
Output 2 (Default = Fire alarm with verification) (374 to 379)
Strobe Output (Default = Strobe – reset after 8 hr) (380 to 385)
Relay Output (Default = Sirens running) (386 to 391)
Codepad Buzzer (Default = Entry/exit plus day alarm) (392 to 397)
1 14 0 0 0 0
2 7 10 2 1 5
2 0 6 4 0 8
1 15 1 0 0 0
0 13 2 1 0 1
The first two locations (from the left) of the output definition provide the Event Code. The options are:
0 0 EDMSAT – satellite siren (Output 1
only)
1 2 Kiss-off received
0 1 System armed 1 3 AUX Power Supply fail
0 2 System disarmed 1 4 AC fail
0 3 Armed in STAY Mode 1 5 Low battery
0 4 Armed in AWAY Mode 1 6 Horn speaker fail
0 5 Pre-arming alert 1 7 Sensor watch alarm
0 6 Exit Warning (all zones sealed) and
entry warning
1 8 Codepad medical alarm
0 7 Exit Warning 1 9 Codepad fire alarm
0 8 Exit Warning finished 1 10 Codepad panic alarm
0 9 Kiss-off after end of Exit Time 1 11 Codepad duress alarm
0 10 Reserved 1 12 Access denied (code retries)
0 11 Entry warning 1 13 Reserved
0 12 Entry warning and day alarm resetting 1 14 Horn speaker (Output 1 only)
0 13 Exit Warning and entry warning and
day alarm resetting
1 15 Sirens running
0 14 Day alarm resetting 2 0 Strobe
0 15 Day alarm latching 2 1 Silent alarm
1 0 Day alarm enabled 2 2 Alarm in STAY Mode
1 1 Telephone line fail 2 3 Alarm in AWAY Mode
Vista de pagina 10