ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters
12 Bosch Security Systems, Inc. | 12/08 | F01U089402-02
Location
Function
Options/Notes Default
2 4 System fault 4 5 Chime
2 5 Fire alarm (resetting) 4 6 Zone not sealed
2 6 Fire alarm (latching) 4 7 Zone not sealed after Exit Time
368 to 397
Outputs
(continued)
2 7 Fire alarm (verification) 4 8 Reserved
2 8 Remote Control 1 4 9 AC MAINS cycle (60 Hz or 50 Hz)
2 9 Remote Control 2 4 10 Reserved
2 10 Remote Control 3 4 11 Reserved
2 11 Radio Control Output 1 4 12 Reserved
2 12 Radio Control Output 2 4 13 Reserved
2 13 Radio Control Output 1 – not in
AWAY Mode
4 14 Reserved
2 14 Radio Control Output 2 – not in
AWAY Mode
4 15 Reserved
2 15 Communications fail after three
attempts
5 0 Reserved
3 0 Communications fail 5 1 Reserved
3 1 Dialer disabled 5 2 Reserved
3 2 Dialer active (on-line) 5 3 Reserved
3 3 Ring detect 5 4 Reserved
3 4 Reserved 5 5 Reserved
3 5 Mimic zone 1 5 6 Reserved
3 6 Mimic zone 2 5 7 Reserved
3 7 Mimic zone 3 5 8 Reserved
3 8 Mimic zone 4 5 9 Reserved
3 9 Mimic zone 5 5 10 Reserved
3 10 Mimic zone 6 5 11 Reserved
3 11 Mimic zone 7 5 12 Reserved
3 12 Mimic zone 8 5 13 Reserved
4 0 Reserved 5 14 Reserved
4 1 Reserved 5 15 Reserved
4 2 Reserved 6 0 Reserved
4 3 Reserved 6 1 Reserved
4 4 Reserved
The third location of the output definition is the output polarity. The options are:
0 Disabled
1 Normally open, going low
2 Normally open, pulsing low
3 Normally open, one shot low
4 Normally open, one shot low (reactivate)
5 Normally open, one shot low (can reset)
6 Normally open, one shot low (alarm)
7 Normally open, latching low
8 Normally low, going open
9 Normally low, pulsing open
10 Normally low, one shot open
11 Normally low, one shot open (reactivate)
12 Normally low, one shot open (can reset)
13 Normally low, one shot open (alarm)
14 Normally low, latching open
The fourth location of the output definition is the time base. The options are:
1 200 ms
2 1 sec
3 1 min
4 1 hr
The fifth and sixth locations of the output definition provide the time base multiplier. Enter a value between
01 and 99.
One Shot Mode
When you program the output polarity as one shot, the time base is multiplied by the time base multiplier.
For example, if the time base = 2 and the multiplier = 05, the output operates for 5 sec.
Pulsing Mode
When you program the output polarity as pulsing, the time base becomes the ON time and the multiplier
becomes the OFF time. The OFF time is the time base, which is multiplied by the multiplier. For example,
if you want the output to pulse 1 sec ON and 5 sec OFF, you would program time base as 2 and the
multiplier as 5.