ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters
8 Bosch Security Systems, Inc. | 12/08 | F01U089402-02
4.0 Programming Parameters
Location
Function
Options/Notes Default
000 to 015
Phone Number 1 - Receiver 1
0 = 10 and telephone termination = 0
anywhere else 0 = 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
016 to 031
Phone Number 2 - Receiver 1
0 = 10 and telephone termination = 0
anywhere else 0 = 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
032
Handshake Tone – Receiver 1
1 HI-LO handshake (contact ID)
2 1400 Hz (Ademco TX @ 1900 Hz)
3 2300 Hz (Sescoa TX @ 1800 Hz)
4 No handshake
5 Pager
1
033
Transmission Format –
Receiver 1
1 Contact ID
2 4 + 2 express
3 FSK 300 baud
4 Domestic
5 Basic pager
1
034 to 039
Subscriber ID Number – Receiver 1
Right justified 0 0 0 0 0 0
040 to 055
Phone Number 1 - Receiver 2
0 = 10 and telephone termination = 0
anywhere else 0 = 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
056 to 071
Phone Number 2 - Receiver 2
0 = 10 and telephone termination = 0
anywhere else 0 = 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
072
Handshake Tone – Receiver 2
1 HI-LO handshake (contact ID)
2 1400 Hz (Ademco TX @ 1900 Hz)
3 2300 Hz (Sescoa TX @ 1800 Hz)
4 No handshake
5 Pager
1
073
Transmission Format –
Receiver 2
1 Contact ID
2 4 + 2 express
3 FSK 300 baud
4 Domestic
5 Basic pager
1
074 to 079
Subscriber ID Number – Receiver 2
Right justified 0 0 0 0 0 0
080
Dialing Format
1 Australian DTMF
2 Australian decadic
3 Alternate DTMF and Australian decadic
4 International DTMF
5 Reversed decadic
6 Alternate DTMF and reversed decadic
1
113 to 142
Telco Arming Sequence (Call Forward On)
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
143 to 158
Telco Disarm Sequence (Call Forward Off)
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
159 to 174
Call Back Telephone Number
0 = 10 and telephone termination = 0
anywhere else 0 = 0
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
175
Ring Count
0 Control panel does not answer
1 to 13 Number of rings until control panel answers
14 Answering machine bypass 2
15 Answering machine bypass 1
8
176
Telephone Line Fail Options
1 Display FAULT indicator when telephone line fails
2 Sound alarm when system arms
4 Sound alarm when system disarms
Options 2 and 4 must be used in conjunction with Option 1
(for example, program 1, 3, 5, or 7).
0
177
Dialer Options 1
1 Dialer reporting functions allowed
2 Remote arming by telephone allowed
4 Answering machine bypass only when armed
8 Bell 103 used for FSK format (Disabled = CCITT V21)
9
178
Dialer Options 2
1 Open/Close Reports only if previous alarm
2 Open/Close Reports for STAY Mode 1 and STAY Mode 2
4 Delay siren until transmission complete
8 Extend handshake wait time from 30 sec to 60 sec
0