ICP-CC404 | Quick Reference Guide | 3.0 Using the System
Bosch Security Systems, Inc. | 12/08 | F01U089402-02 5
Table 3: Codepad Indicators
Data
Value
Zone 1
Indicator
Zone 2
Indicator
Zone 3
Indicator
Zone 4
Indicator
Zone 5
Indicator
Zone 6
Indicator
Zone 7
Indicator
Zone 8
Indicator
MAINS
Indicator
0
1 X
2 X
3 X
4 X
5 X
6 X
7 X
8 X
9 X X
10 X
11 X X
12 X X
13 X X
14 X X
15 X X
2.3 Installer’s Programming
Commands
Installer’s programming commands are used only in
Installer’s Programming Mode.
To execute an installer’s command, enter the
command and press [#].
Table 4 on page 5 shows the installer’s programming
commands.
Table 4: Installer’s Programming Commands
Command Description
959 Test programming key
960 Exit from Installer’s Programming Mode
961 Default system back to factory settings
962 Copy control panel memory to
programming key
963 Copy programming key to control panel
memory
964 Erase programming key
965 Default system for domestic dialing format
966 Enable/disable automatic stepping of
locations when programming
999 Display software version
3.0 Using the System
3.1 Arm the System (On)
3.1.1 AWAY Mode
1. Press and hold [#] until two beeps sound.
Or
− Enter your code and press [#] (for
example, [2 5 8 0 #]).
3.1.2 STAY Mode 1
1. Press and hold [*] until two beeps sound.
Or
− Enter your code and press [*] (for
example,
[2 5 8 0 *]).
3.1.3 STAY Mode 2
Press and hold [0] until two beeps sound.
3.2 Disarm the System (Off)
3.2.1 AWAY Mode
Enter your code and press [#] (for example,
[2 5 8 0 #]).
3.2.2 STAY Mode 1
1. Press and hold [*] until two beeps sound (only if
no alarm).
Or
− Enter your code and press [#] (for
example,
[2 5 8 0 #]).
3.2.3 STAY Mode 2
1. Press and hold [0] until two beeps sound (only if
no alarm).
Or
− Enter your code and press [#] (for
example,
[2 5 8 0 #]).
3.3 Isolating Zones
3.3.1 Standard Isolating
1. Press [*] twice.
2. Enter the zone number to isolate and press [*].
Repeat Step 2 to select other zones.
3. Press [#].