Bosch ICP-CC404 Especificaciones Pagina 13

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 12
ICP-CC404 | Quick Reference Guide | 4.0 Programming Parameters
Bosch Security Systems, Inc. | 12/08 | F01U089402-02 13
Location
Function
Options/Notes Default
398 to 399
Entry Time 1
Location 398: increments of 1 sec (0 to 15 sec)
Location 399: increments of 16 sec (0 to 240 sec)
4
1
400 to 401
Entry Time 2
Location 400: increments of 1 sec (0 to 15 sec)
Location 401: increments of 16 sec (0 to 240 sec)
8
2
402 to 403
Exit Time (AWAY/STAY Modes)
Location 402: increments of 1 sec (0 to 15 sec)
Location 403: increments of 16 sec (0 to 240 sec)
12
3
404 to 405
Entry Guard Time for STAY Mode
Location 404: increments of 1 sec (0 to 15 sec)
Location 405: increments of 16 sec (0 to 240 sec)
0
0
406 to 407
Delay Alarm Report Time
Location 406: increments of 1 sec (0 to 15 sec)
Location 407: increments of 16 sec (0 to 240 sec)
0
0
408 to 409
Sensor Watch Time
Location 408: increments of days (tens digit
Location 409: increments of days (units digit)
0
0
410
Codepad Lockout Time
0 No lockout
1 to 15 Increments of 10 sec (10 sec to 150 sec)
0
411
Siren Run Time
0 No siren time
1 to 15 Increments of 1 min (1 min to 15 min)
5
412
Siren Sound Rate
0 (slowest frequency) to 15 (fastest frequency)
7
413
Auto Arming Pre-Alert Time
0 No pre-alert time
1 to 15 Increments of 5 min (5 min to 75 min)
1
414 to 417
Auto Arming Time
Location 414: Hour of day (tens digit)
Location 415: Hour of day (units digit)
Location 416: Minute of day (tens digit)
Location 417: Minute of day (units digit)
0
0
0
0
418 to 421
Auto Disarming Time
Location 418: Hour of day (tens digit)
Location 419: Hour of day (units digit)
Location 420: Minute of day (tens digit)
Location 421: Minute of day (units digit)
0
0
0
0
422
Kiss-Off Wait Time
0 to 15 Increments of 500 ms (500 ms to 8 sec)
3
423
Reserved
0
424
System Options 1
1 Bosch smart lockout allowed
2 Horn speaker monitor
4 Strobe indication for radio arm/disarm
8 Horn speaker beeps for radio arm/disarm
1
425
System Options 2
1 Codepad panic to be silent
2 Codepad fire to be silent
4 Codepad medical to be silent
8 Access denied (code retries) to be silent
0
426
System Options 3
1 AC fail after 1 hr (disabled = after 2 min)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
8
427
System Options 4
1 Control panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Night arm station or RE005 installed
0
428
Consumer Options 1
1 Test reports only when armed
2 Test report after siren reset
4 Auto arm in STAY Mode 1
8 STAY indicator to display day alarm status
0
429
Consumer Options 2
1 Codepad display extinguish after 60 sec
2 Single button arming allowed (AWAY/STAY Modes 1 and 2)
4 Single button disarming allowed (STAY Modes 1 and 2)
8 Alarm memory reset on disarm
2
430
Consumer Options 3
1 Codepad fault beeps allowed
2 Use digit 3 for codepad duress alarm (instead of digit 9)
4 Alarms activate sirens and strobe outputs in STAY Modes 1 and 2
8 Reserved
5
Vista de pagina 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 23 24

Comentarios a estos manuales