ICP-CC488 | Quick Reference Guide | 2.0 Programming Parameters EN | 14
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
Location
267 to 378 (Continued)
Zone #08 (Default – 24 hr Tamper)
Zone Type 316 9
Zone Pulse Count 317 0
Zone Pulse Count Time 318 0
Zone Options 1 319 1
Zone Options 2 320 12
Report Code 321 1
Dialer Options 322 1
Zone #09 (Default – Instant)
Zone Type 323 15
Zone Pulse Count 324 0
Zone Pulse Count Time 325 0
Zone Options 1 326 1
Zone Options 2 327 14
Report Code 328 1
Dialer Options 329 1
Zone #10 (Default – Instant)
Zone Type 330 15
Zone Pulse Count 331 0
Zone Pulse Count Time 332 0
Zone Options 1 333 1
Zone Options 2 334 14
Report Code 335 1
Dialer Options 336 1
Zone #11 (Default – Instant)
Zone Type 337 15
Zone Pulse Count 338 0
Zone Pulse Count Time 339 0
Zone Options 1 340 1
Zone Options 2 341 14
Report Code 342 1
Dialer Options 343 1
Zone #12 (Default – Instant)
Zone Type 344 15
Zone Pulse Count 345 0
Zone Pulse Count Time 346 0
Zone Options 1 347 1
Zone Options 2 348 14
Report Code 349 1
Dialer Options 350 1
Zone #13 (Default – Instant)
Zone Type 351 15
Zone Pulse Count 352 0
Zone Pulse Count Time 353 0
Zone Options 1 354 1
Zone Options 2 355 14
Report Code 356 1
Dialer Options 357 1
Location
267 to 378 (Continued)
Zone #14 (Default – Instant)
Zone Type 358 15
Zone Pulse Count 359 0
Zone Pulse Count Time 360 0
Zone Options 1 361 1
Zone Options 2 362 14
Report Code 363 1
Dialer Options 364 1
Zone #15 (Default – Instant)
Zone Type 365 15
Zone Pulse Count 366 0
Zone Pulse Count Time 367 0
Zone Options 1 368 1
Zone Options 2 369 14
Report Code 370 1
Dialer Options 371 1
Zone #16 (Default – Instant)
Zone Type 372 15
Zone Pulse Count 373 0
Zone Pulse Count Time 374 0
Zone Options 1 375 1
Zone Options 2 376 14
Report Code 377 1
Dialer Options 378 1
2.6.2 Zone Types
Zone Type Description
0 Instant
1 Handover
2 Delay-1
3 Delay-2
4 Reserved
5 Reserved
6 24 hr Medical
7 24 hr Panic
8 24 hr Hold-up
9 24 hr Tamper
10 Reserved
11 Keyswitch
12 24 hr Burglary
13 24 hr Fire
14 Chime
15 Not Used
2.6.3 Zone Pulse Count
Use the pulse count to program how many pulses (0
to 15) need to be registered within the pulse count
time to activate an alarm.