2.13.2 Event Codes
Event
Code
Description
0 0 EDMSAT – satellite siren (output 1 only)
0 1 System armed
0 2 System disarmed
0 3 Armed in STAY mode
0 4 Armed in AWAY mode
0 5 Pre-arming alert
0 6 Exit Warning (all zones sealed) and entry warning
0 7 Exit Warning
0 8 Exit Warning finished
0 9 Kiss-off after end of Exit Time
0 10 Reserved
0 11 Entry warning
0 12 Entry warning and day alarm resetting
0 13 Exit Warning and entry warning and day alarm
resetting
0 14 Day alarm resetting
0 15 Day alarm latching
1 0 Day alarm enabled
1 1 Telephone line fail
1 2 Kiss-off received
1 3 AUX Power Supply fail
1 4 AC fail
1 5 Low battery
1 6 Horn speaker fail
1 7 Sensor watch alarm
1 8 Codepad medical alarm
1 9 Codepad fire alarm
1 10 Codepad panic alarm
1 11 Codepad duress alarm
1 12 Access denied (code retries)
1 13 Reserved
1 14 Horn speaker (output 1 only)
1 15 Sirens running
2 0 Strobe
2 1 Silent alarm
2 2 Alarm in STAY Mode
2 3 Alarm in AWAY Mode
2 4 System fault
2 5 Fire alarm (resetting)
2 6 Fire alarm (latching)
2 7 Fire alarm (verification)
2 8 Remote control 1
2 9 Remote control 2
2 10 Remote control 3
2 11 Radio control output 1
2 12 Radio control output 2
2 13 Radio control output 1 - not in AWAY Mode
2 14 Radio control output 2 - not in AWAY Mode
2 15 Communications fail after 3 attempts
2.13.2 Event Codes (continued)
Event
Code
Description
3 0 Communications fail
3 1 Dialer disabled
3 2 Dialer active (on-line)
3 3 Ring detect
3 4 Codepad panic (multi-break)
3 5 Mimic zone 1
3 6 Mimic zone 2
3 7 Mimic zone 3
3 8 Mimic zone 4
3 9 Mimic zone 5
3 10 Mimic zone 6
3 11 Mimic zone 7
3 12 Mimic zone 8
3 13 Reserved
3 14 Reserved
3 15 Reserved
4 0 Reserved
4 1 Reserved
4 2 Reserved
4 3 Reserved
4 4 Reserved
4 5 Chime
4 6 Zone not sealed
4 7 Zone not sealed after Exit Time
4 8 Reserved
4 9 AC MAINS cycle (60 Hz or 50 Hz)
4 10 Area 1 – zone unsealed
4 11 Area 2 – zone unsealed
4 12 Reserved
4 13 Reserved
4 14 Reserved
4 15 Reserved
5 0 Reserved
5 1 Reserved
5 2 Area 1 in alarm
5 3 Area 2 in alarm
5 4 Reserved
5 5 Reserved
5 6 Area 1 armed
5 7 Area 2 armed
5 8 Reserved
5 9 Reserved
5 10 Area 1 disarmed
5 11 Area 2 disarmed
5 12 Reserved
5 13 Reserved
5 14 Any areas armed
5 15 Any areas disarmed
6 0 Area 1 codepad data terminal
6 1 Area 2 codepad data terminal
Vista de pagina 17