ICP-CC488 | Quick Reference Guide | 1.0 Overview EN | 9
Bosch Security Systems, Inc. | 12/08 | F01U089458-02
1.13 Telephone Monitor Mode (Toggle
On/Off)
1. Enter the four character Installer Code, followed
by [6] and the [#] key (for example, [1 2 3 4 6
#]).
2. Press and hold the [9] key until two beeps are
heard to send a test report.
Table 6: Telephone Monitor Mode
Zone LED Dialing Event
1 Telephone Line Seized
2 Dialing Telephone Number
3 Handshake Received
4 Data Being Sent
5 Kiss-Off Received
None Released Telephone Line
You must exit from Telephone Monitor
Mode to resume normal operations.
1.14 Add/Delete User Code/RF Keyfob
1.14.1 Add A User Code
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (1 to 16) you want to
add/change, followed by the [#] key.
3. Enter the new code, followed by the [#] key.
1.14.2 Add RF Keyfob
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (9 to 16) you want to
add, followed by the [#] key.
3. Enter the 9-digit RF keyfob ID number, followed
by the [#] key.
1.14.3 Delete a User Code/RF Keyfob
1. Enter the four character Master Code, followed
by [1] and the [#] key (for example, [2 5 8 0 1
#]).
2. Enter the User Number (1 to 16) you want to
delete, followed by the [#] key.
3. Press the [*] key to delete the User Code.
1.15 Change Domestic Telephone
Numbers
1. Enter the four character Installer Code or Master
Code, followed by [2] and the [#] key (for
example, [1 2 3 4 2 #]).
2. Enter the digits for the telephone number.
3. If there is more than one telephone number,
press the [*] key, followed by the [4] key (inserts
break between phone numbers) and repeat Step
2, or press the [#] key to exit.
1.16 Turn Outputs On/Off
1. Enter the four character Master Code, followed
by [5] and the [#] key (for example, [2 5 8 0 5
#]).
2. Enter the Output Number (1 to 3) you want to
toggle on or off.
3. Press the [#] key to toggle on or the [*] key to
toggle off.
4. Press the [#] key to exit.
1.17 Setting Date and Time
1. Enter the four character Master Code, followed
by [6] and the [#] key (for example, [2 5 8 0 6
#]).
2. Enter the day (DD), month (MM), and year (YY)
followed by the hour (HH) and minute (MM).
3. Press the [#] key to exit.
1.18 Day Alarm – Toggle On/Off
Press and hold the [4] key until two beeps are heard.
Day alarm toggles on or off.
1.19 STAY Mode 2 Zones – Program
1. Enter the four character Installer Code or Master
Code, followed by [4] and the [#] key (for
example, [1 2 3 4 4 #]).
2. Enter the Zone Number you want the system to
automatically isolate, followed by the [*] key.
Repeat if more than one zone must be
automatically isolated when armed in STAY
Mode 2.
3. Press the [#] key to exit.