K2200 Series | User Guide | 6.0 Installer Commands EN | 45
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
6.1.7 Using the D Command
Each of the settings in the D command is fully
described above.
1. Present an editor key to the faceplate reader.
2. Enter the password and press [ENT], if required.
3. You will now see the CMD prompt.
4. Type [D] and press [ENT].
CMD D_
5. Use the up and down arrow keys to select the
door.
Enter a value, in seconds, between 0 and 255 for
the amount of time the lock will operate. Press
[ENT].
DR 1 LRT 5
Press [NXT] to go to the next field.
6. A value greater than zero enables door
monitoring. The value entered is the time in
seconds that, when added to the lock release
time, a door left open warning will be generated.
Press [ENT]
DR 1 TP 0
Press [NXT] to go to the next field.
7. Lock Mode Options - This is an option field. To
change a setting press the number corresponding
to the option you want to change. If an option is
set, its number will be displayed, if not set, a -
(dash) will be displayed.
Table 19: Lock Mode Options
Option Description
Unset
Fail-secure lock
1
Set
Fail-safe lock
Unset
Normal RTE, door contact
2
Set
Emergency override, free exit
Unset
Normal RTE report
3
Set
Request for entry report
Unset
No AVR module
4
Set
AVR module attached
Unset
No alarm module
5
Set
Alarm module attached
Unset
Normal operation
6
Set
Exit out of hours allowed
Unset
No PIN reader with time profiles
7
Set
PIN reader with time profiles
attached
8
Not Used, leave Unset
Press [ENT] when all required options are set.
Press [NXT] to go to the next field.
8. Door 1, Lock Mode 2 (Options) - This display
consists of 8 more option settings represented
either by a number or a - (dash). Each setting is
changed by pressing a number between 1 and 8.
When set, the number will appear: when not set,
a - (dash) will replace the number. At startup, all
settings will be off.
DR 1 M2--------
Table 20: Lock Mode 2 Options
Options Description
Set:
RTE with no lock output. This is
designed for use on the secure
side of a door where exit is via a
mechanical handle, etc. Pressing
the Request to Exit switch shunts
the door contact but does not
activate the lock.
1
Unset:
RTE with lock output. This is the
default setting. When the Request
to Exit switch is pressed, the lock
state is changed and the door can
be opened.
Set:
Early lock release time. When set,
the lock is de-activated a maximum
of two seconds after the door is
opened.
Unset:
lock release time operates normally
2
Lock is de-activated when the lock release
time expires or the door closes.
Set:
Log authorized event only when
door opened. When set,
authorized events are only reported
if the door is opened.
3
Unset:
All events are logged whether or
not the door is opened
4
Elevator
Control:
This option is not user
configurable and is set using
Readykey for Windows
5 – 8
These settings are not currently used.
Press [NXT] to go to the next field. (Remember
to press [ENT] to save changes).
9. PIN Reader Time Profile - Only used when a
Readykey PIN reader with time profiles is
attached. When the time profile is active, only a
valid key is required; when inactive, a valid key
plus PIN is required for access. A time profile of
0 requires a valid key plus PIN at all times. Press
[ENT].
DR 1 PINTP 0
Press [ESC] to return to the CMD prompt.