K2200 Series | User Guide | Appendix A: Transactions EN | 56
Bosch Security Systems | 7/03 | 17376 v1.1 / 47491C
Table 25: Transactions
Transaction Description Priority
Editor On
(Panel)
An operator has entered the Editor at the faceplate.
[1218] 02/12/93 15:02 MASTER KEY Editor On (Panel)
Emergency
Override Off
Using a special lock mode option, the request to exit input can be used to monitor an
emergency break-glass (manual pull station.) This transaction occurs when the switch is
restored.
[1326] 02/12/93 16:10 DOOR NAME Emergency Override Off
Emergency
Override On
Using a special lock mode option, the request to exit input can be used to monitor an
emergency break-glass (manual pull station.) This transaction occurs when the switch is
broken.
[1325] 02/12/93 16:10 DOOR NAME Emergency Override On
Entry
Authorized
A key has been allowed through an access point that was set as an entry point. This would
be channel 1 or 2 on a Readykey K2200 or channel 1 on a Readykey K1200. Entry and exit
points are only used when Lock Sharing or Passback features are used.
[1321] 02/12/93 16:06 DOOR NAME KEYHOLDER Entry Authorized
Exit
Authorized
A key has been allowed through an access point that was set as an exit point. This would be
channel 3 or 4 on a Readykey K2200 or channel 2 on a Readykey K1200. Entry and exit
points are only used when Lock Sharing or Passback features are used.
[1322] 02/12/93 16:06 DOOR NAME KEYHOLDER Exit Authorized
Exit Out of
Hours
A key has been allowed to pass through an exit door, although a time profile would not
normally let the key through. A special lock mode option needs to be set on the door to allow
this feature.
[1342] 02/12/93 16:06 DOOR NAME KEYHOLDER Exit Out of Hours
Free Exit This is a special condition where a door contact is fitted but no request to exit button is
used. Every time the door opens without a key being used this transaction will be generated.
A special lock mode option is required.
[1327] 02/12/93 16:10 DOOR NAME Free Exit
Incorrect PIN
Entry
A keyholder has made 5 attempts to enter a PIN at a K2001-P reader without success. That
key will not be accepted for 2 hours.
[1306] 02/12/93 15:59 DOOR NAME KEYHOLDER Incorrect PIN Entry
Local Alarm
Accepted
An alarm has been accepted at the door controller by presenting an Editor key.
[1237] 02/12/93 15:14 DOOR NAME MASTER KEY Local Alarm Accepted
Local Duress
Accepted
A PIN Duress Alarm has been accepted by an operator at the door controller
[1320] 02/12/93 16:03 DOOR NAME MASTER KEY Local Duress Accepted
Local
Override
Accept
An Override Alarm has been accepted by an operator at the door controller.
[1365] 02/12/93 16:20 DOOR CTRLR 1 MASTER KEY Local Override Accept
Manual
Engage
An alarm module input has been switched on by an operator.
[1359] 02/12/93 16:16 ZONE 2 Manual Engage
Manual
Isolate
An alarm module input has been disabled by an operator.
[1357] 02/12/93 16:16 ZONE 2 Manual Isolate
Manual Lock An operator has manually locked a door unlocked by a time profile, or previously unlocked
manually.
[1343] 02/12/93 16:14 DOOR NAME MASTER KEY Manual Lock