CC880/LP880, SC8016 | Quick Reference Guide | 5. Programming Parameters EN | 16
Bosch Security Systems | 6/04 | 4998152461B
5.11 PET Pager Programming
5.11.1 PET Pager Network Password
Location
514 to 529
Location Default
514 7
515 0
516 6
517 1
518 7
519 3
520 7
521 3
522 7
523 7
524 6
525 4
526 to 529 0
Telecom expects to see the password “passwd” sent
before the message is transmitted. The password is
programmed using ASCII text.
5.11.2 PET Pager ID Number
The Pager ID Number locations store the unique
number that allows the network to identify individual
pagers. When programming the system to report
using SMS messaging to a mobile phone, enter the
mobile phone number as the PET pager ID number.
To program the Pager ID Number, enter the decimal
characters that represent the Pager ID Number.
Remember to substitute a ten for a zero and to
terminate the number with a zero as you would if
you were programming the telephone numbers.
Location
530 to 539
Default
0
5.12 Outputs Programming
5.12.1 Outputs
Location
540 to 623
Location Default
Output 1 (Default = EDMSAT)
Event Code 540 0
Event Code 541 0
Polarity 542 0
Time Base 543 0
Time Base Multiplier 544 0
Time Base Multiplier 545 0
Output 2 (Default = EDMSAT)
Event Code 546 0
Event Code 547 0
Polarity 548 0
Time Base 549 0
Time Base Multiplier 550 0
Time Base Multiplier 551 0
5.12.1 Outputs (continued)
Location
540 to 623
Location Default
Strobe Output (Default = Smoke Detector Reset)
Event Code 552 0
Event Code 553 1
Polarity 554 10
Time Base 555 2
Time Base Multiplier 556 0
Time Base Multiplier 557 3
Output 4 (Default = Strobe)
Event Code 558 2
Event Code 559 0
Polarity 560 1
Time Base 561 0
Time Base Multiplier 562 0
Time Base Multiplier 563 0
Output 5 (Default = Sirens Running)
Event Code 564 1
Event Code 565 15
Polarity 566 1
Time Base 567 0
Time Base Multiplier 568 0
Time Base Multiplier 569 0
Output 6 (Default = Codepad – Entry/Exit + D Alarm)
Event Code 570 0
Event Code 571 12
Polarity 572 2
Time Base 573 1
Time Base Multiplier 574 0
Time Base Multiplier 575 1
Output 7 (Default = Area 1 in Alarm – Siren)
Event Code 576 5
Event Code 577 2
Polarity 578 6
Time Base 579 3
Time Base Multiplier 580 1
Time Base Multiplier 581 0
Output 8 (Default = Area 1 in Alarm – Strobe)
Event Code 582 5
Event Code 583 2
Polarity 584 6
Time Base 585 3
Time Base Multiplier 586 6
Time Base Multiplier 587 0
Output 9 (Default = Area 2 in Alarm – Siren)
Event Code 588 5
Event Code 589 3
Polarity 590 6
Time Base 591 3
Time Base Multiplier 592 1
Time Base Multiplier 593 0