CC880/LP880, SC8016 | Quick Reference Guide | 6. Connections EN | 25
Bosch Security Systems | 6/04 | 4998152461B
6.3 Connections for Split EOL Resistors for 16 Zone Operation Using N/O Contacts
Figure 3: Connections for Split EOL Resistors for 16 Zone Operation Using N/O Contacts
2
2
1
3
3
1
4
6
5
7
88
4
6
10
8
9
1 = +12 V
2 = Zone input
3 = Zone
4 = EOL 3K3
5 = EOL 1K
6 = EOL 6K8
7 = EOL 4K7
8 = N/O
9 = N/C
10 = 4K7
6.4 Codepad Connections (Partitioning)
Figure 4: Code Connections (Partitioning) – Master Plus Four Areas
1
2
3
4
5
6
6
6
6
6
1 = Master codepad
2 = Area 1 codepad
3 = Area 2 codepad
4 = Area 3 codepad
5 = Area 4 codepad
6 = DATA
Program the following locations for the Area
Addressable (CP500A) codepads to
function correctly:
OUT1 – Location 540 = 6; Location 541 = 0
OUT2 – Location 546 = 6; Location 547 = 1
OUT3 – Location 552 = 6; Location 553 = 2
OUT4 – Location 558 = 6; Location 559 = 3