CC880/LP880, SC8016 | Quick Reference Guide | 4. Programming Commands EN | 9
Bosch Security Systems | 6/04 | 4998152461B
Table 5: Telephone Monitor Mode
Zone LED Dialling Event
1 Telephone line seized
2 Dialling telephone number
3 Handshake received
4 Data being sent
5 Kiss-off received
None Released telephone line
4.3.8 Add a User Code
1. Enter the four character Master Code followed
by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the user number you want to add/change
followed by the [#] key.
3. Enter the new code followed by the [#] key.
4.3.9 Delete a User Code (V1.10)
1. Enter the four character Master Code followed
by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the user number you want to delete
followed by the [#] key.
3. Press the [#] key to delete the user code.
4.3.10 Delete a User Code (V1.20+)
1. Enter the four character Master Code followed
by [1] and the [#] key (for example,
[2 5 8 0 1 #]).
2. Enter the user number you want to delete
followed by the [#] key.
3. Press the [*] key to delete the user code.
4.3.11 Change Domestic Telephone Numbers
1. Enter the four character Master Code followed
by [2] and the [#] key (for example,
[2 5 8 0 2 #]).
2. Enter the digits for the telephone number.
3. If more than one telephone number, press the [*]
key and repeat Step 2, or press the [#] key to
exit.
4.3.12 Turn Outputs On/Off
1. Enter the four character Master Code followed
by [5] and the [#] key (for example,
[2 5 8 0 5 #]).
2. Enter the output number (1 to 5) that you want to
toggle on or off.
3. Press the [#] key to toggle on or the [*] key to
toggle off.
4. Press the [#] key to exit.
4.3.13 Set Date and Time
1. Enter the four character Master Code followed
by [6] and the [#] key (for example,
[2 5 8 0 6 #]).
2. Enter the day (DD), month (MM), and year (YY)
followed by the hour (HH) and minute (MM).
3. Press the [#] key to exit.
4.3.14 Day Alarm – Toggle On/Off (V1.10)
Enter the four character Master Code followed by [7]
and the [#] key (for example, [2 5 8 0 7 #]).
4.3.15 Day Alarm – Toggle On/Off (V1.20+)
Press and hold the [4] key until two beeps are heard.
4.3.16 STAY Mode 2 Zones - Program
1. Enter the four character Master Code followed
by [8] and the [#] key (for example,
[2 5 8 0 8 #]).
2. Enter the zone number you want the system to
automatically isolate followed by the [*] key.
Repeat if more than one zone must be
automatically isolated when armed in STAY
Mode 2.
3. Press the [#] key to exit.
4.3.17 Fault Analysis
1. Press and hold the [5] key until two beeps are
heard.
2. Zone indicators display fault conditions (see
Table 6).
3. Press [#] key to exit.
Table 6: Fault Analysis
Zone LED FAULT Condition
1 Battery low
2 Date/time reset
3 Sensor watch fail
4 Horn speaker fail
5 Telephone line fail
6 EPROM fail
7 Fuse fail
8 Communication fail
4.3.18 Modem Call (Alarm Link)
Press and hold the [6] key until two beeps sound.
4.3.19 Latching Outputs (Reset)
Press and hold the [7] key until two beeps sound.