CC880/LP880, SC8016 | Quick Reference Guide | 5. Programming Parameters EN | 21
Bosch Security Systems | 6/04 | 4998152461B
5.20 Consumer Options Programming
5.20.1 Consumer Options 1 (V1.10, V1.20+)
Location
669 (V1.10 only)
1 Entry guard time in STAY Mode
2 Audible alarm in STAY Mode allowed
4 User code required to isolate zones
8 Codepad Extinguish Mode allowed
Location
669 (V1.20+)
1 STAY LED to display day alarm on/off status
2 Audible alarm in STAY Mode allowed
4 AUX LED to display dialler on-line (partitioned
codepad only)
8 Codepad Extinguish Mode allowed
5.20.2 Consumer Options 2
Location
670
1 User Code + 0 + AWAY function to arm/disarm all
areas allowed
2 Single button arming allowed (AWAY/STAY Modes
1 and 2)
4 Single button disarming allowed (STAY Modes 1
and 2)
8 Alarm reset memory on disarm
5.20.3 DTMF Command Module Options
Location
671
Default
0
1 Access to installer’s programming mode allowed
2 Installer code functions allowed
4 Disarming and auxiliary code functions allowed
8 Master code functions allowed
5.20.4 Expansion Board Options (V1.10, V1.20)
Location
672 (V1.10)
Default
0
1 Zone expansion board installed
2 Output expansion board installed
4 Momentary keyswitch input
8 Latching keyswitch input
Location
672 (V1.20)
Default
0
1 Zone expansion board installed
2 Output expansion board installed
3 Momentary keyswitch input
4 Latching keyswitch input
5 Momentary arm in AWAY Mode
6 Momentary arm in STAY Mode 1
7 Momentary arm in STAY Mode 2
8 Momentary disarm
9 Momentary arm area 4
10 Momentary disarm area 4
11 Momentary arm/disarm area 4
12 Latching arm/disarm area 4
5.21 Telephone Line Fail Options
Location
673
Default
0
1 Display FAULT indicator if telephone line fails
2* Sound alarm when system is armed if telephone
line fails
4* Sound alarm when system is disarmed if telephone
line fails
* Options 2 and 4 must be used in conjunction with Option
1 (for example, program a 1, 3, 5, or 7).
5.22 Open/Close Reports Programming
5.22.1 Open/Close Reports for Area 2
Location
674 to 675
Location Default
Open Report 674 0
Close Report 675 0
5.22.2 Open/Close Reports for Area 3
Location
676 to 677
Location Default
Open Report 676 0
Close Report 677 0
5.22.3 Open/Close Reports for Area 4
Location
678 to 679
Location Default
Open Report 678 0
Close Report 679 0
5.23 Subscriber ID Programming
5.23.1 Subscriber ID Number for Area 2
Location
680 to 683
Default
0
5.23.2 Subscriber ID Number for Area 3
Location
684 to 687
Default
0
5.23.3 Subscriber ID Number for Area 4
Location
688 to 691
Default
0
5.24 Zone Allocations Programming
5.24.1 Zone Allocations for Area 1
Location
692 to 699
Location Default
Zone 1 LED – Area 1 Codepad 692 0
Zone 2 LED – Area 1 Codepad 693 0
Zone 3 LED – Area 1 Codepad 694 0
Zone 4 LED – Area 1 Codepad 695 0
Zone 5 LED – Area 1 Codepad 696 0
Zone 6 LED – Area 1 Codepad 697 0
Zone 7 LED – Area 1 Codepad 698 0
Zone 8 LED – Area 1 Codepad 699 0