6. Connections
6.1 Connection for Momentary or Latching Keyswitch
Figure 1: Connection for Momentary or Latching Keyswitch
1
1 = Momentary or latching keyswitch
To enable the connection for a momentary or
latching keyswitch on the above diagram, refer to
“LOCATION 672” under Expansion Board Type to
program these options.
6.2 Connections for Split EOL Resistors for 16 Zone Operation
Figure 2: Connections for Split EOL Resistors for 16 Zone Operation
GND
+12V
+12V
Z8
Z7
Z6
Z5
GND
+12V
Z4
Z3
Z2
Z1
+12V
1
8
7
6
5
4
32
7
8 8 8
6 6 6
7
1 = Standard eight zone (3K3) configuration
2 = 3K3 EOL Zone 1
3 = 16 Zone (3K3/6K8) configuration
4 = 6K8 EOL Zone 9
5 = If N/O switches are used, both zones will trip if
either N/O switch is closed.
6 = N/O
7 = N/C
8 = EOL