CC880/LP880, SC8016 | Quick Reference Guide | 4. Programming Commands EN | 8
Bosch Security Systems | 6/04 | 4998152461B
4.1 Arming the System (On)
4.1.1 AWAY Mode
Press and hold the [#] key until two beeps are heard.
Or
Enter your code followed by the [#] key (for
example, [2 5 8 0 #]).
4.1.2 STAY Mode 1
Press and hold the [*] key until two beeps are heard.
Or
Enter your code followed by the [*] key (for example,
[2 5 8 0 *]).
4.1.3 STAY Mode 2
Press and hold the [0] key until two beeps are heard.
4.1.4 Arm All Areas in AWAY Mode
(Partitioning)
Enter your code followed by [0] and then the [#] key
(for example, [2 5 8 0 *]).
Use this code to arm all areas that the code is
assigned simultaneously to in AWAY Mode without
arming each area individually.
4.2 Disarming the System (Off)
4.2.1 AWAY Mode
Enter your code followed by the [#] key (for
example, [2 5 8 0 #]).
4.2.2 STAY Mode 1
Press and hold the [*] key until two beeps are heard
(only if no alarm).
Or
Enter your code followed by the [#] key (for
example, [2 5 8 0 #]).
4.2.3 STAY Mode 2
Press the [0] key until two beeps are heard (only if no
alarm).
Or
Enter your code followed by the [#] key (for
example, [2 5 8 0 #]).
4.2.4 Disarm All Areas (Partitioning)
Enter your code followed by [0] and then the [#] key
(for example, [2 5 8 0 *]).
Use this code to disarm all areas that the code is
assigned simultaneously without disarming each area
individually.
4.3 Isolating Zones
4.3.1 Standard Isolating
1. Press the [*] key twice.
2. Enter the zone number you want isolated
followed by the [*] key.
Repeat Step 2 if more than one zone must be
isolated.
3. Press the [#] key to exit when finished.
4.3.2 Code to Isolate
1. Press the [*] key once.
2. Enter your user code.
3. Enter the zone number you want isolated
followed by the [*] key.
Repeat Step 2 if more than one zone must be
isolated.
4. Press the [#] key to exit when finished.
4.3.3 Set First Test Report
1. Enter the four character Installer Code followed
by [2] and the [#] key (for example,
[1 2 3 4 2 #]).
2. Enter the number of days (0 to 99) to wait until
the first test report followed by the [#] key.
4.3.4 Event Memory Recall
Enter the four character Installer Code or Master
Code followed by [3] and the [#] key (for example,
[1 2 3 4 8 #]).
The last 40 events (non-partitioned) or last ten events
(partitioned) are displayed in reverse order (for
example, most recent to least recent).
4.3.5 Walk Test Mode
1. Enter the four character Installer Code or Master
Code followed by [4] and the [#] key (for
example, [1 2 3 4 4 #]).
2. Test each zone as required.
3. Press the [#] key to exit.
4.3.6 Satellite Siren Service Mode
Enter the Installer Code followed by [5] and the [#]
key (for example, [1 2 3 4 5 #]).
4.3.7 Telephone Monitor Mode (Toggle
On/Off)
1. Enter the four character Installer Code followed
by [7] and the [#] key (for example,
[1 2 3 4 7 #]).
2. Press and hold the [9] key until two beeps sound
to send a Test Report.
3. When complete, repeat Step 1 to turn the
Telephone Monitor Mode off.