CC880/LP880, SC8016 | Quick Reference Guide | 7. Wiring Diagrams EN | 28
Bosch Security Systems | 6/04 | 4998152461B
7.2 Component Overlays
Figure 7: Component Overlay 1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1 = Termination for phone line
2 = Line fault module (note polarity)
3 = Socket for telecom lead connection
4 = DTMF command module (note polarity)
5 = Voice module, modem module, or phone
amplifier (not polarity)
6 = Optional 8 zone expander/8 channel output
board plugs
7 = Zone termination strip
8 = Default switch
9 = Relay contact
10 = Battery consumption LED (When illuminated,
indicates power is being drawn from the
battery.)
11 = Remove link for dry contact
12 = Output termination strip
13 = Programming key or programmer plugs
14 = Battery input
15 = Plug pack input (Bosch Security Systems
TF008)
16 = 3 A battery fuse
17 = 1 A accessory fuse (for external equipment)