IntuiKey Series | Instruction Manual | Controlling System4 Video Multiplexers
Bosch Security Systems | 28 June 2004
EN
|
34
6.2 Programming/Controlling MUX
Functions
6.2.1 Password Entry
If a password is required by the multiplexer on-screen
display, you must press ENTER after each number entered for
the password (e.g. if the password is 1-2-3-4, you then press
1, then ENTER, 2, then ENTER, etc.).
FIGURE 6-2 System4 Mux Main Control Menu
6.2.2 MUX Main Control Menu Command
Descriptions
The MUX Main Control menu, displayed on the softkey
display, uses the softkey buttons to execute commands or
to gain access to other submenus for additional
programming/configuration. Detailed command
descriptions follow. Refer to the Multiplexer
Instruction Book for additional information.
Exit
Exits one menu and returns to the main menu for
the particular function being programmed.
Full Screen
Select Full Screen Camera Mode by pressing the Full
Screen softkey. The camera currently selected by
the keyboard will be displayed in full screen on the
monitor.
Quad Screen
Divides the screen into four separate areas. Enable
Quad Screen Mode by pressing the Quad Screen key
once. Pressing the key additional times cycles
through different viewing configurations.
Multiscreen
Enables multiscreen displays. The capabilities of
the multiplexer model under control determine the
available configurations.
• 6-channel: 5+1
• 9-channel: 4+3, 3x3
• 16-channel:4+3, 8+2, 12+1, 3x3, and
4x4
NOTE: Pressing the multiscreen softkey multiple times
cycles through the possible selections.
Select Cameo Segment
When in Multi or Quad Mode, the screen area where
a camera is displayed is called a cameo. Press the
Cameo softkey to enter the cameo selection mode.
In this mode, joystick is used to select which cameo
window will be under control of the keyboard.
Entering a number into the keyboard while in this
mode will cause the camera to appear in the
currently selected cameo window. Cameras may be
assigned to any selected cameo, and may be
changed as often as required. The Intuikey’s
numeric entry field title will change to Cameo while
the DVR is in this Mode. Press the Cameo softkey
again to exit the mode.
NOTE: The multiplexer function of Assigning All
Cameras is provided by an additional softkey on the
MUX Main Control menu. Press this key to activate this
function.
Sequence
Runs a previously programmed camera sequence.
Toggle VCR Test Mode
Enables/disables the multiplexer’s VCR test mode.
When in VCR test mode, the IntuiKey status
display shows the VCR icon.
Record
Activates VCR record mode and displays the REC
indicator in the IntuiKey status display. Press the
softkey again to disable the record mode.
Play
Activates VCR play mode and displays the PLAY
indicator in the IntuiKey status display. Press the
softkey again to disable the play mode.