IntuiKey Series | Instruction Manual | Controlling System4 Video Multiplexers
Bosch Security Systems | 28 June 2004
EN
|
37
f. Select MUX
Pressing this softkey displays a short message on the
softkey display indicating that entry of a multiplexer
address is required. The IntuiKey status display
changes to the display in FIGURE 6-7.
FIGURE 6-7
Upon entering an Allplex number, press ENTER.
The keyboard determines whether the selected
multiplexer is present. If it is not, an error is
displayed, and the keyboard reverts to the last
known acceptable Allplex number.
g. MUX Audio
This toggle button is used to enable or disable the
keyboard audio beeper that sounds in response to
MUX error messages or alarm/action events.
Enabling or disabling this option affects all MUX’s
connected to the keyboard.
6.3 MUX Error Messages
7TROUBLESHOOTING
7.1 System
1. No text on displays:
• Ensure that power is applied to the keyboard
through at least one of the following:
• MUX RJ-11 Cable
• Allegiant RJ-11 Cable
• DC Power Supply Jack
• It is possible that the LCD contrast has been
adjusted to a point that makes the displays
unreadable. Pressing MON and CLR
simultaneously resets the contrast to a central
position for readability. Once the contrast is
reset, select KEYBOARD CONTROL from
the Product menu, then the CONTRAST
ADJUST softkey and set the LCD contrast for
optimal viewability.
2. No LCD or keyboard backlight:
•KBD Backlighting is provided at a low level,
which may not be apparent in bright lighting
conditions.
3. LCD appears to have bad pixels:
•To verify LCD operation, from the Product menu,
select KEYBOARD CONTROL; then, select
LCD Test to cycle the LCDs through a number
of tests.
7. 2 K eyboard
1. When in the Product menu, DVR or Multiplexer is
missing:
•Unique address has not been set in the video
devices. Use the front panel controls to access
the appropriate on-screen menu to assign
address and starting camera numbers. The
IntuiKey will not properly recognize video
devices if there are conflicting addresses in the
system.
• Check all interconnect cables for cut or broken
wires between the keyboard and other devices.
Address
--
Multiplexer
Error Name Description
Error 1 No Communication The keyboard cannot
communicate with the
multiplexer.
Error 2 Invalid Keyboard Entry An invalid number has been
entered on the keyboard
Error 3 Invalid Multiplexer Number A multiplexer number less
than 1 or greater than 30
was entered.
Error 4 Multiplexer Not Found No multiplexers were found
during search.