Bosch SE2005 Guia de preparacion Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 54
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
Security Escort | Installation and Setup Guide | 1.0
S
y
stem Overview
EN | 10
Bosch Security Systems | 1/09 | 33831E
Power output: 9 VDC output for
SE485 or for ProxLink Radio Module
power
Driver outputs:
- Strobe: 500 mA solid state sink,
terminal switches to ground in
an alarm condition.
- Siren: 500 mA solid state sink,
terminal switches to ground in
an alarm condition.
Multiplex buses: eight multiplex
driver buses for power and
communication to receivers or alert
units
Communication interface to central
console: selectable SE485 or RS-232
Keyswitch input: Optional 47k EOL
resistor, supervised loop
1.3.4 EA102 Receiver
Description
The EA102 Receivers are located
throughout the grounds and building
interiors. Each receiver contains a
radio receiver to detect the
transmissions from transmitters.
Multiple receivers detect the same
transmission and send the signal
information to the transponder so the
system can identify the transmitting
device, transmitting information, and
location. The receiver also reports
housing tampering and radio jamming to
the transponder.
Indoor receivers are typically mounted
on inside walls and have one red and
one green LED. The green LED is used
to indicate a successful Test of a
personal transmitter. The red LED is
illuminated during alarms. Each
receiver contains a piezo-electric
horn that can be activated if the
receiver detected an alarm
transmission
Outdoor receivers are contained in
small weatherproof boxes typically
mounted on the sides of buildings and
on light posts. Outdoor receivers do
not have the visible red and green
LED’s. Outdoors, the strobe lights on
the alert units should be used to
acknowledge successful test and alarm.
Specifications
Enclosure:
- Indoor: AE100 indoor enclosure
- Outdoor: AE101 outdoor enclosure
Temperature range: -40°C to +65°C
(-40°F to
+149°F)
Power source: 12 VDC, 25 mA
typical, 55 mA with horn sounding,
supplied from the transponder MUX
bus
Antenna type: Diversity antennas
protected within enclosures
1.3.5 EA120 Alert Unit
Description
This is a control module that
communicates with the transponder on
the MUX Bus. The alert unit can be
used to activate strobe and siren
units or optional other switched
devices. The alert unit also reports
tampering, AC power loss, and backup
battery level to the transponder.
Specifications
Enclosures:
- Indoor: AE1 small indoor metal
- Outdoor: AE101 outdoor fiber
Temperature range: -40°C to +65°C
(-40°F to +149°F)
Power source: 18 VAC, 50 VA (can
use TR1850, 110 VAC to 18 VAC
transformer)
Battery backup: 12 VDC lead acid
battery
Driver outputs:
- Power: 1 A maximum, intended as
the supply source for strobe and
siren
-
Strobe: 500 mA solid state sink,
terminal switches to ground in
an alarm condition
- Siren: 500 mA solid state sink,
terminal switches to ground in
an alarm condition
Vista de pagina 9