Security Escort | Installation and Setup Guide |5.0 Testing
and Troubleshootin
g
EN | 41
Bosch Security Systems | 1/09 | 33831E
1. Enable the Test Mode by placing the
P4 jumper across both pins (jumper
P5 removed).
The red LED turns ON and stays
ON during the test. This
indicates that power is properly
connected and the receiver is in
Test Mode. If the red LED does
not come on, check the POWER+
and POWER- wiring to this
receiver. Also verify the
corresponding transponder bus
enable jumper is in place and
the transponder is on and
powered.
The green LED flickers if the
receiver is connected to a
working transponder. If the
green LED is not flashing verify
the BUS+ and BUS– wiring to this
receiver (note: this is a rapid
flashing).
There is no data transmitted to
the central station. Therefore
the central console reports this
receiver as “Not responding”
while the receiver is in Test
Mode.
2. Activate the transmitter from
different locations near the
receiver.
The red and green LEDs respond
to a received transmission.
If the receiver detected all the
packets from the transmission,
the sounder sounds.
3. Remove the P4 jumper to return the
receiver to normal operating mode.
5.2.3 Receiver Spacing Mode
Refer to Section
2.3.1 Verify Each
Potential Receiver Location to
determine receiver location and
spacing.
5.3 Transponder
5.3.1 Status LEDs
Each transponder contains LEDs that
display the transponder’s condition
and its response to events. With the
exception of the AC Power LED (which
is located in the lower right corner
of the transponder circuit board), the
diagnostic LEDs are located in the top
right corner of the transponder board.
Generally, the LEDs indicate the
unit’s status and signal system
events. Each LED and its function is
indicated in
Table 9:
Figure 20: EA500 Diagnostic LEDs
Bus 0
Bus 1
Bus 2
Bus 3
Bus 4
Bus 5
Bus 6
Bus 7
Comm Fail
Carrier Detect
Transmit Data
Receive Data
CRC Error
Test in Porgress
Alarm in Progress
Heartbeat
1
1- Transponder address
Figure 21: EA501 Diagnostics LEDs
OFF
ON
Comm Fail/Bus Fault
Carrier Detect
Transmit Data
Receive Data
CRC Error
Test in Porgress
A
larm in Progress
Heartbeat
1
2
1 - Transponder address
2 - 12 VDC battery connector