Security Escort | Installation and Setup Guide |3.0
Installation Instructions
EN | 32
Bosch Security Systems | 1/09 | 33831E
Figure 11: Back of AE100 Enclosure
1
2
1 - Use with single-gang electrical
boxes.
2 - Use with 9 cm (3.5 in.) square
electrical boxes.
Note:
The enclosure does not currently
support octagonal electrical boxes.
3.3.4 AE101 Outdoor Enclosure
This enclosure houses the receiver or
alert unit. It is suitable for outdoor
installation. See Section
1.7.4 AE101
Outdoor Enclosure for specifications.
Note:
Do not use this enclosure if you
intend to allow user feedback
through the sounder and LEDs of the
receiver.
Figure 12: Inside AE101 Enclosure
3.4 Mounting and Setting Up
Components
3.4.1 EA102 Receiver Installation
Mounting
Mount the electronic assembly to the
enclosure. Leave at least 10 cm (4
in.) of wire hanging out of the unit.
Do not leave extra wire inside the
enclosure as this could impact the
receiving antennas.
Set the Address
Every module on each multiplex bus of
the transponder must have its own
address. Set the address on the alert
unit using the address switch. See the
EA102 Installation Instructions.
Use only address numbers 0 through 7.
Do NOT use address numbers 8 and 9.
3.4.2 EA500 Transponder Installation
Mounting
Mount the electronic assembly to the
enclosure using the hardware kit
provided. See
Figure 13 and Figure 14
for mounting location.
Set the Address
Every transponder in the system must
have a unique address. Set the address
on the transponder using the DIP
switches in the upper-right corner.
Use the chart included in the
transponder’s Installation Guide for
the correct address settings.
Wiring
Connect the bus wires.
Connect the tamper switch wires.
Connect the serial cable or SE485
wires (set the proper switch
position).
Connect the output siren/strobe if
used.
Connect the keyswitch if used.
Connect 9 V output to ProxLink or
SE485 if used.