Example
To program Phone Number 1 for Destination 1 as
96721233 and the Account Number for Destination 1
as 9876:
1. Enter the Installer Code and press [#] to enter
Installer’s Programming Mode.
For example, [1 2 3 4 #].
2. Enter [0 #] to move to Location 000.
3. Enter:
[9 * # 6 * # 7 * # 2 * # 1 * # 2 * # 3 * # 3 *] to
program Phone Number 1 for Destination 1 as
96721233.
4. Enter [3 4 #] to go to Location 034.
5. Enter [0 * # 0 * # 9 * # 8 * # 7 * # 6 * #] to
program Account Number for Destination 1 as
9876.
6. Enter [9 6 0 #] to exit from the Installer’s
Programming Mode.
7.1 Programming Option Bit Locations
Option bit locations enable you to program any
combination of up to four different options within
the same location. This feature saves time
programming and reduces the number of locations to
be programmed.
Example
If at Location 177 you only want options 1, 2, and 4,
add the numbers together and the total is the
number to be programmed. For example, the
number to be programmed is 7 (1 + 2 + 4 = 7).
Table 2: Location 177 Programming Option
Bits
Option Description
1 Dialer reporting functions allowed.
2 Remote arming by telephone allowed.
4 Answering machine bypass only when armed.
8 Use Bell 103 for FSK format
(disabled = CCITT V21).
8.0 Using the System
8.1 Assigning RF Sensors
Before programming the wireless sensors, you must
assign each RF sensor to a zone. You can assign up
to 16 wireless RF sensors to the ICP-VR8488
Intruder Alarm System across eight separate zones.
RF sensors 1 to 8 are already assigned to their
corresponding zone (for example, RF Sensor 1 is
assigned to Zone 1, RF Sensor 2 is assigned to Zone
2, and so on).
You assign RF sensor devices to Zones 1 to 8 by
programming Locations 616 to 623. Each location
represents an RF sensor device. You can assign
multiple RF sensors to the same zone.
8.2 Adding RF Sensors
Do the procedure below to program the ID number
of each RF sensor into the system. The RF sensor is
assigned to the zone mapped in Locations 616 to
623.
1. Enter the Installer Code and press [0 #].
For example, [1 2 3 4 0 #].
2. Enter the RF sensor number (1 to 16) to add and
press [#].
For example [1 #] to add Sensor 1 or [1 6 #] to
add Sensor 16.
3. Enter the nine-digit ID number found on the RF
sensor and press [#].
For example, [0 0 0 3 8 7 9 4 1 #].
8.3 Deleting RF Sensors
To delete an RF sensor:
1. Enter the Installer Code and press [0 #].
For example, [1 2 3 4 0 #].
2. Enter the RF sensor number (1 to 16) to delete
and press [#].
For example, [1 #] to delete Sensor 1 or [1 6
#] to delete Sensor 16.
3. Press [*] to delete the RF sensor from the system.
8.4 Adding RF Keyfobs
The ICP-VR8488 supports a total of 16 users. Users
1 to 8 are assigned as PIN codes and Users 9 to 16
are assigned as remote radio RF codes. Follow the
steps outlined below to add RF keyfobs.
1. Enter your Master Code and press [1 #].
For example, [2 5 8 0 1 #].
2. Enter the user number (9 to 16) to add and press
[#].
For example, [9 #] to add RF Keyfob 1 or
[1 6 #] to delete RF Keyfob 8.
3. Enter the nine-digit ID number found on the RF
keyfob and press [#].
For example, [0 0 8 0 2 1 6 2 9 #].
8.5 Deleting RF Keyfobs
To delete an RF keyfob:
1. Enter your Master Code and press [1 #].
For example, [2 5 8 0 1 #].
2. Enter the user number (9 to 16) to delete and
press [#].
For example, [9 #] to delete RF Keyfob 1 or [1 6
#] to delete RF Keyfob 8.
3. Press [*] to delete the RF keyfob from the
system.
8.6 Arming the System (On)
8.6.1 AWAY Mode
Press and hold [#] until two beeps sound.
Or
Enter your code and press [#].
For example, [2 5 8 0 #].