Event Codes (continued)
Event
Code
Description
3 4 Codepad Panic (multibreak) v1.05+
3 5 Mimic zone 1
3 6 Mimic zone 2
3 7 Mimic zone 3
3 8 Mimic zone 4
3 9 Mimic zone 5
3 10 Mimic zone 6
3 11 Mimic zone 7
3 12 Mimic zone 8
3 13 Reserved
3 14 Reserved
3 15 Reserved
4 0 Reserved
4 1 Reserved
4 2 Reserved
4 3 Reserved
4 4 Reserved
4 5 Chime
4 6 Zone not sealed
4 7 Zone not sealed after exit time
4 8 Reserved
4 9 AC MAINS cycle (60 Hz or 50 Hz)
4 10 Area 1 – zone unsealed
4 11 Area 2 – zone unsealed
4 12 Reserved
4 13 Reserved
4 14 Reserved
4 15 Reserved
5 0 Reserved
5 1 Reserved
5 2 Area 1 in alarm (CC488 only)
5 3 Area 2 in alarm (CC488 only)
5 4 Reserved
5 5 Reserved
5 6 Area 1 armed (CC488 only)
5 7 Area 2 armed (CC488 only)
5 8 Reserved
5 9 Reserved
5 10 Area 1 disarmed
5 11 Area 2 disarmed
5 12 Reserved
5 13 Reserved
5 14 Any areas armed (CC488 only)
5 15 Any areas disarmed (CC488 only)
6 0 Area 1 codepad data terminal (CC488 only)
6 1 Area 2 codepad data terminal (CC488 only)
Polarity (Modes)
Option Description
0
Output not used
1
Normally open, going low
2
Normally open, pulsing low
3
Normally open, one shot low
4
Normally open, one shot low (reactivate)
5
Normally open, one shot low (can reset)
6
Normally open, one shot low (alarm)
7
Normally open, latching low
8
Normally low, going open
9
Normally low, pulsing open
10
Normally low, one shot open
11
Normally low, one shot open (reactivate)
12
Normally low, one shot open (can reset)
13
Normally low, one-shot open (alarm)
14 Normally low, latching open
Time Base
Option Description
1 200 ms
2 1 sec
3 1 min
4 1 hour
Time Base Multiplier
Enter a value between 01 and 99.
One Shot Mode
When you program the output polarity as one shot,
the time base is multiplied by the time base
multiplier. For example, if the time base = 2 and the
multiplier = 05, the output operates for 10 sec.
Pulsing Mode
When you program the output polarity as pulsing,
the time base becomes the ON time and the
multiplier becomes the OFF time. The OFF time is
the time base, which is multiplied by the multiplier.
For example, if you want the output to pulse 1 sec
ON and 5 sec OFF, you would program time base as
1 and the multiplier as 5.
Entry Time 1
Location
466 to 467
Location Default
Increments of 1 sec
(0 to 15 sec)
466
4
Increments of 16 sec
(0 to 240 sec)
467
1
Entry Time 2
Location
468 to 469
Location Default
Increments of 1 sec
(0 to 15 sec)
468
8
Increments of 16 sec
(0 to 240 sec)
469
2
Vista de pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30 31 32

Comentarios a estos manuales

Sin comentarios