8.18 Toggle Day Alarm On/Off
Press and hold [4] until two beeps sound.
Day Alarm toggles on or off.
8.19 STAY Mode 2 Zones - Program
1. Enter the Installer Code or your Master Code
and press [4 #].
For example, [1 2 3 4 4 #].
2. Enter the zone number the system should
automatically isolate and press [*].
3. Repeat Step 2 to select another zone to be
automatically isolated when armed in STAY
Mode 2.
4. Press [#] to exit.
8.20 Fault Analysis
1. Press and hold [5] until two beeps sound.
2. The zone indicators display the fault condition.
Refer to Table 4 on page 16.
3. Press [#] to exit.
Table 4: Fault Indicators
Zone
Indicator
Fault Description Hold Down Button Zone Indicator Fault Condition
1 System Fault 1 1 Battery Fail
2 Date and Time
3 RF Receiver Fail
4 Horn Speaker Fail
5 Telephone Line Fail
6 EEPROM Fault
7 AUX Power Supply Fail
8 AC Fail
2 RF Low Battery 2 1 to 8 Zones 1 to 8 RF Low Battery
3 Zone Tamper Alarm 3 1 to 8 Zones 1 to 8 Tamper Alarm
4 Sensor Watch Fault 4 1 to 8 Zones 1 to 8 Sensor Watch Fail
5 RF Sensor Watch 5 1 to 8 Zones 1 to 8 RF Sensor Watch Fail
6 Communication Fail 6 1 Receiver 1 Fail
2 Receiver 2 Fail
8.21 Modem Call (Alarm Link)
Press and hold [6] until two beeps sound.
8.22 Latching Outputs (Reset)
Press and hold [7] until two beeps sound.
8.23 Codepad ID/Buzzer Tone
Press and hold [8] until you hear the desired buzzer
tone.
8.24 Test Report
Press and hold [9] until two beeps sound.
8.25 Speaker Test
Press and hold [1] until two beeps sound.
The speaker sounds for 2 sec.
8.26 Bell Test
Press and hold [2] until two beeps sound.
The piezo siren sounds for 2 sec.
8.27 Strobe Test (Toggle On/Off)
1. To turn the strobe on, press and hold [3] until
three beeps sound.
2. To turn the strobe off, press and hold [3] until
two beeps sound.
8.28 Telco Arm Sequence (Call Forward
On)
This option allows you to enable the Call Forward –
Immediate On sequence or Call Forward – No
Answer sequence that automatically operates when
you arm the system in the AWAY Mode.
1. Enter the Installer Code or your Master Code
and press [3 #].
For example, [1 2 3 4 3 #].
2. Enter [1 #].
3. Enter the Call Forward On sequence.
4. Press [#] to exit.
8.29 Telco Disarm Sequence (Call
Forward Off)
This option allows you to disable the Call Forward –
Immediate On sequence or Call Forward – No
Answer sequence that automatically operates when
you arm the system in the AWAY Mode.
1. Enter the Installer Code or your Master Code
and press [3 #].
For example, [1 2 3 4 3 #].
2. Enter [2 #].
3. Enter the Call Forward Off sequence.
4. Press [#] to exit.