ICP-VR8488 | Quick Reference Guide | 9.0 Programming Guide EN | 22
Bosch Security Systems, Inc. | 12/08 | F01U089640-01
Codepad Reporting Options
Location
411
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
System Status – AUX Power Supply Fail Report
Location
412 to 413
Location Default
Tens digit
412
10
Units digit
413
3
System Status – AUX Power Supply Fail Restore
Report
Location
414 to 415
Location Default
Tens digit
414
10
Units digit
415
8
System Status – AC Fail Report
Location
416 to 417
Location Default
Tens digit
416
10
Units digit
417
2
System Status – AC Fail Restore Report
Location
418 to 419
Location Default
Tens digit
418
10
Units digit
419
7
System Status – Low Battery Report
Location
420 to 421
Location Default
Tens digit
420
10
Units digit
421
1
System Status – Low Battery Restore Report
Location
422 to 423
Location Default
Tens digit
422
10
Units digit
423
6
System Status – Access Denied (Code Retry)
Location
424 to 426
Location Default
Code retry limit
(0 = unlimited)
424
6
Tens digit
425
7
Units digit
426
12
System Status Reporting Options
Location
427
0 No Codepad Alarm Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails
Test Report Time (Automatic)
Location
428 to 434
Location Default
Hour of day (tens digit)
428
0
Hour of day (units digit)
429
0
Minute of day (tens digit)
430
0
Minute of day (units digit)
431
0
Test Report (tens digit)
432
7
Test Report (units digit)
433
1
Repeat interval in days
434
0
Test Reporting Dialer Options
Location
435
0 No Test Reports allowed
1 Report to Receiver 1
2 Report to Receiver 2
4 Report to both Receiver 1 and Receiver 2
8 Report to Receiver 2 only if Receiver 1 fails