Exit Time (AWAY/STAY Modes)
Location
470 to 471
Location Default
Increments of 1 sec
(0 sec to 15 sec)
470
12
Increments of 16 sec
(0 sec to 240 sec)
471
3
Entry Guard Time For STAY Mode
Location
472 to 473
Location Default
Increments of 1 sec
(0 sec to 15 sec)
472
0
Increments of 16 sec
(0 sec to 240 sec)
473
0
Delay Alarm Report Time
Location
474 to 475
Location Default
Increments of 1 sec
(0 sec to 15 sec)
474
0
Increments of 16 sec
(0 sec to 240 sec)
475
0
Sensor Watch Time
Location
476 to 477
Location Default
Increments of days
(tens digit)
476
0
Increments of days
(units digit)
477
0
Codepad Lockout Time
Location
478
Default
0
0 No lockout
1 to 15 Increments of 10 sec
(10 sec to 150 sec)
Siren Run Time
Location
479
Default
5
0 No siren time
1 to 15 Increments of 1 min
(1 min to 15 min)
Siren Sound Rate
Location
480
Default
7
0 to 15 0 = slowest frequency
15 = fastest frequency
Auto Arming Pre-Alert Time
Location
481
Default
1
0 No pre-alert time
1 to 15 Increments of 5 min
(5 min to 75 min)
Auto Arming Time
Location
482 to 485
Location Default
Hour of the day (tens digit)
482
0
Hour of the day (units digit)
483
0
Minute of the day (tens digit)
484
0
Minute of the day (units digit)
485
0
Auto Disarming Time
Location
486 to 489
Location Default
Hour of the day (tens digit)
486
0
Hour of the day (units digit)
487
0
Minute of the day (tens digit)
488
0
Minute of the day (units digit)
489
0
Kiss-Off Wait Time
Location
490
Default
3
Increments of 500 ms
(500 ms to 8 sec)
Speaker Beep Volume
Location
491
Default
13
0 to 15 0 = no beeps
15 = loudest beeps
System Options 1
Location
492
1 Bosch smart lockout allowed
2 Horn speaker monitor
4 Strobe indication for radio arm/disarm
8 Assign Button 4 on transmitter to operate STAY
Mode
System Options 2
Location
493
Default
0
1 Codepad panic to be silent
2 Codepad fire to be silent
4 Codepad medical to be silent
8 Access denied (code retries) to be silent
System Options 3
Location
494
1 AC fail after 1 hour (Disabled = after 2 min)
2 Ignore AC fail
4 Pulse count handover allowed
8 Handover delay to be sequential
System Options 4
Location
495
Default
0
1 Panel to power up disarmed (if power reset)
2 Arm/disarm tracking on power up
4 Internal crystal to keep time
8 Night arm station or RE005 installed
Vista de pagina 24