Arming The System
There are several different ways to arm the system depending on whether you are leaving the
premises and require all active zones to be in a ready state for an intruder, or, if you are
remaining in the premises and only require part of the system to be in a ready state for an
intruder.
If a zone is not sealed at the end of exit time, the zone will be automatically isolated and will
be constantly displayed on the codepad. The zone will again become an active part of the
system when the zone has restored (ie. If a window is left open after exit time has expired,
the window will not be an active part of the system until the window has closed. Opening
the window after exit time has expired will cause an alarm condition).
The different methods for arming the system include:
AWAY Mode
Arms the entire system. Refer to Arming In AWAY Mode on page 10.
STAY Mode 1
Arms all zones except those programmed to be automatically isolated by the installer.
Refer to Arming In STAY Mode 1 on page 11.
STAY Mode 2
Arms all zones except those programmed to be automatically isolated by the Master
Code holder. Refer to Arming In STAY Mode 2 on page 12.
Forced Arming
The feature of arming the system when a zone is not sealed is known as forced arming. If
the system does not arm and a long beep is heard, forced arming is not permitted. If this is
the case, you must ensure that all zones are sealed or manually isolated before you can arm
the system. Refer to Isolating Zones on page 15 for more information.
Arming In AWAY Mode
When you leave your premises and require all zones to be in a ready state to detect intrusion,
you would arm the system in AWAY Mode.
There are two different methods for arming the system in AWAY Mode. Method one is
standard and will always operate. Method two is optional and may be disabled by your
installer if you do not wish to use single button arming.
Method One
How To Arm The System In AWAY Mode
1. Enter your user code followed by the # button (eg. 2580#).
Two beeps will be heard and the AWAY indicator will display. Exit time will now
commence counting.
Method Two
How To Arm The System In AWAY Mode
1. Press and hold the # button until two beeps are heard.
The AWAY indicator will display and exit time will commence counting.