Isolating Zones
Isolating zones allow you to manually disable one or more zones before arming the system.
Once a zone has been isolated, access is allowed into that zone during the armed state
without activating an alarm.
An example when you may require to isolate a zone before arming the system could be when
a PIR detector may be false alarming or that you may need to leave a pet inside a particular
zone whilst you are away.
Isolating zones is performed by one of two methods. Method two is optional and only
allows those user codes programmed by your installer to have access to isolate zones.
Standard Isolating
Standard isolating allows all operators to be able to isolate zones without the need to know a
valid user code.
How To Isolate A Zone
1. Press the * button twice to enter the isolating mode.
Three beeps will be heard and the STAY indicator will flash.
2. Enter the zone number (1 – 16) that you wish to select to isolate followed by the *
button. (eg. 1* = Zone 1, 16* = Zone 16 etc).
As you select each zone to be isolated, you will notice that the corresponding zone
indicator will begin to flash. If you selected an incorrect zone to be isolated, enter the
incorrect zone number again followed by the * button.
Repeat Step 2 if more than one zone is required to be isolated until all zone that are
required to be isolated have been selected.
3. Press the # button after you have selected all zones to be isolated.
Two beeps will be heard and the system will return to the disarmed state.
!"#$%&"'()* Operators Manual 15
Electronics Design and Manufacturing Pty Limited ISSUE160.DOC
Comentarios a estos manuales