Arming In STAY Mode 1
STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be
armed to detect any would be intruder from entering the premises and at the same time,
allowing you to move freely within an area that has been automatically isolated. Only your
security company can program zones to be automatically isolated in STAY Mode 1.
There are two different methods for arming the system in STAY Mode 1. Method one is
standard and will always operate. Method two is optional and may be disabled by your
installer if you do not wish to use single button arming.
Entry Guard Timer For STAY Mode
When arming the system in STAY Mode 1, an optional entry timer called Entry Guard
Timer For STAY Mode may be used to delay the sirens if a zone that has not been
automatically isolated has triggered into alarm condition. Entry Guard Timer For STAY
Mode is the delay time used for all zones except 24-hour zones when the system is armed in
STAY Mode 1 or STAY Mode 2.
If the Entry Guard Timer For STAY Mode has been programmed and a zone that has not
been automatically isolated has triggered, the codepad will beep twice a second until the
Entry Guard Timer For STAY Mode has expired or the system has been disarmed. If the
alarm condition has not been reset by entering your user code followed by the # button (eg.
2580#) before the Entry Guard Time For STAY Mode expires, the sirens will activate into
alarm. Only your installer can program this feature.
Method One
How To Arm The System In STAY Mode 1
1. Enter your user code followed by the * button (eg. 2580*).
Two beeps will be heard and the STAY indicator will display. Exit time will now
commence counting.
Any zones that have been programmed to be automatically isolated in STAY Mode 1
will flash until exit time expires. At the end of exit time, all zones selected to be
automatically isolated will extinguish and the codepad will give one short beep.
Method Two
How To Arm The System In STAY Mode 1
1. Press and hold the * button until two beeps are heard.
The STAY indicator will display and exit time will now commence counting.
Any zones that have been programmed to be automatically isolated in STAY Mode 1
will flash until exit time expires. At the end of exit time, the zone indicators will
extinguish and the codepad will give one short beep.
!"#$%&"'()* Operators Manual 11
Electronics Design and Manufacturing Pty Limited ISSUE160.DOC