Term Description
Hand Held Remote
Control
Can be used to remotely operate your system via hand held transmitters (Also
known as RF keyfobs).
Isolating
Allows you to manually disable (isolate) one or more zones before arming the
system.
Master Code
Is a numerical code used for arming and disarming the system as well as allowing
access to functions such as adding and deleting user codes etc.
Master Partitioned
Codepad
This codepad can only be used if your system has been partitioned (CC488 Only).
The codepad allows you to view and operate both areas from the same codepad.
Monitoring Station
Is a secure location where a digital receiver monitors numerous alarm systems and
deciphers their alarm transmission reports. The operator can then advise the
appropriate authorities to take immediate action.
Panic Alarm
This type of alarm indicates to the monitoring station that there is an emergency
situation at your premises.
Phone Controller
The phone controller can be used to turn your system on in AWAY mode via the
telephone by generating a tone.
Sealed
Refers to zone status. If a zone is sealed, the detection device is not violated an
d
the zone indicator will not be displayed on the codepad.
Sensor Watch
Sensor watch gives the control panel the ability to recognise that detection devices
may have stopped working or that the view to a PIR detector has been blocked,
thus unable to detect any movement over the duration of the time programmed by
your installer.
Silent Alarm
Your installer may program zones for silent operation. This means that when the
zone programmed for silent operation has been violated during the armed period,
your alarm system will communicate with the monitoring station without sounding
the sirens.
STAY Mode 1
Is a condition that automatically isolates zones when your system is armed in
STAY Mode 1. Only your installer can program zones to be isolated automatically
in STAY Mode 1.
STAY Mode 2
Is a condition that automatically isolates zone when your system is armed in STAY
Mode 2. Only the Master Code holder can program zones to be isolated
automatically in STAY Mode 2.
Telco Arm Sequence
Telco arming is a feature that automatically calls the telephone exchange an
d
diverts your telephone number to another telephone when the system is armed in
AWAY Mode (In Australia, this feature is called “Call Forward”).
Telco Disarm Sequence
Telco disarming automatically calls the telephone exchange and un-diverts you
r
telephone number.
Unsealed
Refers to zone status. A zone is unsealed when a zone has been violated. The
corresponding zone indicator will display on the codepad.