03. Radio jamming
The Carephone 61/62 sends a technical message to the monitoring centre
when a radio signal from another device disturbs it. Check the tick-box to
enable this function.
25. Radio transmission monitoring
The Carephone 61/62 can monitor the wireless transmitters that are
assigned. The wireless transmitters send a signal to the Carephone 61/62
at regular intervals. A failure message is sent to the monitoring centre if
the Carephone 61/62 does not receive this signal at least once a week.
Check the tick-box to enable this function.
28. Call forwarding
It is possible for the monitoring centre, if it supports this functionality, to
command the Carephone 61/62 to forward the current call to a new
destination using a specified protocol. You can allow the Carephone 61/62
to use the specified protocol or force it to use telephone protocol. This
function is only possible with protocols RB2000E (target 0), CPC (target 3)
and RBIP (target 9). Choose between:
– 0 = forwarding to another number, 1 = forwarding to a telephone.
30. Device number
When an emergency call is made, this number is sent to the monitoring
centre. The number can be up to 12 digits long. Numbers 0000, 9998, 9999
and 999999 may not be used. Default value is 1248.
31. Sign in / sign out
To specify whether the sign in or sign out of the activity monitor will
initiate a call to a call recipient. Check the tick-box to enable this function.
32. Call progress tones audible
You can choose to hear the call progress tones when the Carephone makes
a call. Check the tick-box to enable this function.