32 en | Programming steps Configuration Manager
970.129b | V2 | 2014.05 User Manual Bosch Security Systems
You have also access to extended programming features:
In steps 121, 122, etc, select the activation start and end time
for each RF detector, in steps of 15 minutes.
In steps 201, 202, etc, select the custom alarm type for each
RF detector. It must be a 3-digit value from 0 to 999.
Select also the custom event handler:
– emergency event (personal).
Choose this setting in the case of a person triggering the
alarm. Notice: this resets the activity monitor.
– emergency event (environmental)
Choose this setting in the case of a non-personal event
triggering the alarm, such as a detector.
– silent event, with the listen-in function. The alarm receiving
centre has the ability to control the speak/listen
connection.
In steps 251, 252, etc, select the location code for each RF
detector. Choose a number between 0 and 99 corresponding to
a location code as described in the BS8521 protocol.
CAUTION!
Steps 201, 202, etc. must only be used in case of a transmitter
in BS8521 protocol! Otherwise, alarms will not be transmitted!
CAUTION!
The location code (steps 251, 252) must only be used in the
case of a transmitter in BS8521 protocol! Otherwise, alarms
will not be transmitted!