Configuration Manager Programming steps | en 23
Bosch Security Systems User Manual 970.129b | V2 | 2014.05
72. Activate output
The Carephone 61/62 provides a potential-free relay output with a
normally open switch contact. Program the way the output reacts:
0 = off
1 = speak / listen connection and repeated emergency call
3 = outgoing emergency call
4 = incoming call recognition
5 = wireless transmitter
6 = remote activation
7 = speak / listen connection
8 = pre-alarm
9 = pre-alarm and speak / listen connection
Default value is 0.
73. Assign input
The Carephone 61/62 provides external inputs. The function assigned can
be programmed:
0 = external activity monitor reset
1 = emergency call button
2 = service call
3 = external input
9 = fire alarm
B = motion detection
Default value is 3 - External input.
73. Input is
After assigning the input, the input can be chosen as a:
0 = normally open contact (closing)
1 = normally closed contact (opening)